Call: +7 771 977 66 65, +7 705 421 2277
Sign in or Register
My basket

Astana Biomed Group, an authorized Abcam distributor in Central Asia

Abiomed homepage

  • Categories
    Signal Transduction
    Cancer
    Epigenetics and Nuclear Signaling
    Immunology
    Cell Biology
    Cardiovascular
    Neuroscience
    Tags & Cell Markers
    Kits/ Lysates/ Other
    Developmental Biology
    Microbiology
    Biochemicals
    Secondary antibodies
    Isotype/Loading Controls
    Antibody Arrays
  • About us
  • Partners
  • Contact
    Address

    Saryarka 32, 18, 010000, Astana city, Kazakhstan

    Telephone +7 771 977 66 65, +7 705 421 2277

    Email

    laboratory@ctlab.kz, orders@abiomed.kz

Back to category

HRP Anti-Aurora A antibody [35C1] (ab199220)

HRP Anti-Aurora A antibody [35C1] (ab199220)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)

Key features and details

  • HRP Mouse monoclonal [35C1] to Aurora A
  • Suitable for: WB
  • Reacts with: Human
  • Conjugation: HRP
  • Isotype: IgG2b

You may also be interested in

Product image
Recombinant Human Ephrin A3 protein (denatured) (ab156351)
Product image
Recombinant Human MTH1 protein (ab99390)
Product image
FITC Anti-Cytokeratin 18 antibody [C-04] (ab52459)
Product image
Human PEDF ELISA Kit (ab246535)

Overview

  • Product name

    HRP Anti-Aurora A antibody [35C1]
    See all Aurora A primary antibodies
  • Description

    HRP Mouse monoclonal [35C1] to Aurora A
  • Host species

    Mouse
  • Conjugation

    HRP
  • Tested Applications & Species

    Application Species
    WB
    Human
    See all applications and species data
  • Immunogen

    Recombinant full length protein corresponding to Human Aurora A.

  • Positive control

    • WB: Jurkat whole cell lysate.

Properties

  • Form

    Liquid
  • Storage instructions

    Shipped at 4°C. Store at +4°C short term (1-2 weeks). Upon delivery aliquot. Store at -20°C or -80°C. Avoid freeze / thaw cycle. Store In the Dark.
  • Storage buffer

    pH: 7.40
    Preservative: 0.1% 10% Proclin 300 Solution
    Constituents: PBS, 30% Glycerol (glycerin, glycerine), 1% BSA
  • Concentration information loading...
  • Purity

    IgG fraction
  • Clonality

    Monoclonal
  • Clone number

    35C1
  • Myeloma

    Sp2/0-Ag14
  • Isotype

    IgG2b
  • Research areas

    • Cell Biology
    • Cell Cycle
    • Cell Division
    • Spindle
    • Signal Transduction
    • Protein Phosphorylation
    • Ser / Thr Kinases
    • Aurora
    • Cancer
    • Cell cycle
    • Cell division
    • Cancer
    • Tumor biomarkers
    • Other

Images

  • Western blot - HRP Anti-Aurora A antibody [35C1] (ab199220)
    Western blot - HRP Anti-Aurora A antibody [35C1] (ab199220)
    HRP Anti-Aurora A antibody [35C1] (ab199220) at 1/5000 dilution + Jurkat (Human T cell lymphoblast-like cell line) Whole Cell Lysate at 20 µg

    Developed using the ECL technique.

    Performed under reducing conditions.

    Predicted band size: 45 kDa
    Observed band size: 50 kDa
    why is the actual band size different from the predicted?


    Exposure time: 12 minutes


    This blot was produced using a 4-12% Bis-tris gel under the MOPS buffer system. The gel was run at 200V for 50 minutes before being transferred onto a Nitrocellulose membrane at 30V for 70 minutes. The membrane was then blocked for an hour using 3% milk before being incubated with 199220 overnight at 4°C. Antibody binding was visualised using ECL development solution ab133406.

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Alternative products to HRP Anti-Aurora A antibody [35C1] (ab199220)

  •  
  • Product image

    Anti-Aurora A antibody (ab115883)

    Applications: IHC-P

  •  
  • Product image

    Alexa Fluor® 555 Anti-Aurora A antibody [35C1] (ab217712)

    Applications: ICC/IF

  •  
  • Product image

    Anti-Aurora A (phospho S342) antibody (ab111410)

    Applications: IHC-P

  •  
  • Product image

    Anti-Aurora A antibody (ab61114)

    Applications: IHC-P, WB

  •  
  • Product image

    PE Anti-Aurora A antibody [35C1] (ab216698)

    Applications: Flow Cyt

  •  
  • Product image

    Anti-Aurora A antibody [EPR5026] - Centrosome Marker (ab108353)

    Applications: Flow Cyt, ICC/IF, IP, WB

  •  
  • Product image

    Anti-Aurora A antibody - Centrosome Marker (ab1287)

    Applications: IHC-P, IP, WB

  •  
  • Product image

    Anti-Aurora A (phospho T288) antibody (ab83968)

    Applications: ICC/IF

  •  
  • Product image

    Anti-Aurora A antibody [35C1] - BSA and Azide free (ab264552)

    Applications: ELISA, Flow Cyt, ICC, ICC/IF, IHC-Fr, IHC-P, IP, WB

Clear all

Recently viewed products

  •  
  • Product image

    Anti-CCL4/MIP-1 beta antibody [EPR494] (ab40857)

  •  
  • Product image

    Anti-UBE2C antibody [EPR23165-31] - BSA and Azide free (ab269592)

  •  
  • Product image

    Anti-TOP3B antibody [EP7779] - C-terminal (ab183520)

  •  
  • Product image

    Anti-PDZRN4 antibody [EPR11852] - BSA and Azide free (ab249638)

  •  
  • Product image

    Anti-FABP-1 antibody [8D2BB12] (ab113693)

  •  
  • Anti-Interferon alpha 2 antibody [N39] (ab24101)

Get resources and offers direct to your inbox Sign up
© 2021 Astana Biomed Group LLP. All rights reserved.