Human CD137 ELISA Kit (ab229892)
Key features and details
- One-wash 90 minute protocol
- Sensitivity: 8.2 pg/ml
- Range: 46.9 pg/ml - 3000 pg/ml
- Sample type: Cell culture extracts, Cell culture supernatant, Cit plasma, EDTA Plasma, Hep Plasma, Serum
- Detection method: Colorimetric
- Assay type: Sandwich (quantitative)
- Reacts with: Human
Overview
-
Product name
Human CD137 ELISA Kit
See all CD137 kits -
Detection method
Colorimetric -
Precision
Intra-assay Sample n Mean SD CV% Spiked serum 5 2.4% Inter-assay Sample n Mean SD CV% Spiked serum 3 2.8% -
Sample type
Cell culture supernatant, Serum, Cell culture extracts, Hep Plasma, EDTA Plasma, Cit plasma -
Assay type
Sandwich (quantitative) -
Sensitivity
8.2 pg/ml -
Range
46.9 pg/ml - 3000 pg/ml -
Recovery
Sample specific recovery Sample type Average % Range Serum 88 87% - 89% Cell culture extracts 100 99% - 104% Cell culture media 104 98% - 107% Hep Plasma 81 80% - 82% EDTA Plasma 84 82% - 85% Cit plasma 90 86% - 92% -
Assay time
1h 30m -
Assay duration
One step assay -
Species reactivity
Reacts with: Human -
Product overview
Human CD137 ELISA Kit (ab229892) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of CD137 protein in cell culture extracts, cell culture supernatant, cit plasma, edta plasma, hep plasma, and serum. It uses our proprietary SimpleStep ELISA® technology. Quantitate Human CD137 with 8.2 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
- Single-wash protocol reduces assay time to 90 minutes or less
- High sensitivity, specificity and reproducibility from superior antibodies
- Fully validated in biological samples
- 96-wells plate breakable into 12 x 8 wells stripsA 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
-
Notes
Abcam has not and does not intend to apply for the REACH Authorisation of customers’ uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses. -
Platform
Pre-coated microplate (12 x 8 well strips)
Properties
-
Storage instructions
Store at +4°C. Please refer to protocols. -
Components 1 x 96 tests 10X Human CD137 Capture Antibody 1 x 600µl 10X Human CD137 Detector Antibody 1 x 600µl 10X Wash Buffer PT (ab206977) 1 x 20ml 5X Cell Extraction Buffer PTR (ab193970) 1 x 10ml Antibody Diluent 4BI 1 x 6ml Human CD137 Lyophilized Recombinant Protein 2 vials Plate Seals 1 unit Sample Diluent NS (ab193972) 1 x 50ml SimpleStep Pre-Coated 96-Well Microplate (ab206978) 1 unit Stop Solution 1 x 12ml TMB Development Solution 1 x 12ml -
Research areas
-
Function
Receptor for TNFSF14/4-1BBL. Possibly active during T cell activation. -
Tissue specificity
Expressed on the surface of activated T-cells. -
Sequence similarities
Contains 4 TNFR-Cys repeats. -
Cellular localization
Membrane. - Information by UniProt
-
Alternative names
- 4 1BB
- 4 1BB ligand receptor
- 4-1BB ligand receptor
see all -
Database links
- Entrez Gene: 3604 Human
- Omim: 602250 Human
- SwissProt: Q07011 Human
- Unigene: 654459 Human
- Unigene: 86447 Human
Images
-
SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
-
Background-subtracted data values (mean +/- SD) are graphed.
-
Background-subtracted data values (mean +/- SD) are graphed.
-
The concentrations of CD137 were measured in duplicates, interpolated from the CD137 standard curves and corrected for sample dilution. Undiluted samples are as follows: serum 50%, plasma (citrate) 25%, plasma (heparin) 50% and plasma (EDTA) 50%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).
-
The concentrations of CD137 were measured in duplicates, interpolated from the CD137 standard curves and corrected for sample dilution. Undiluted samples are as follows: cell culture supernatant 50%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).
-
Extract based on 500 µg/mL extract load. The concentrations of CD137 were measured in duplicate and interpolated from the CD137 standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean CD137 concentration was determined to be 537 pg/mL in Stimulated THP-1 cell extract, and undetectable in unstimulated THP-1 cell extract.
-
To learn more about the advantages of recombinant antibodies see here.