Anti-COX IV antibody [EPR9442(ABC)] - BSA and Azide free (ab231168)
Key features and details
- Produced recombinantly (animal-free) for high batch-to-batch consistency and long term security of supply
- Rabbit monoclonal [EPR9442(ABC)] to COX IV - BSA and Azide free
- Suitable for: WB, IHC-P, ICC/IF, Flow Cyt, IP
- Reacts with: Mouse, Rat, Human
Overview
-
Product name
Anti-COX IV antibody [EPR9442(ABC)] - BSA and Azide free
See all COX IV primary antibodies -
Description
Rabbit monoclonal [EPR9442(ABC)] to COX IV - BSA and Azide free -
Host species
Rabbit -
Tested Applications & Species
See all applications and species dataApplication Species Flow Cyt HumanICC/IF HumanIHC-P HumanIP Human -
Immunogen
This information is proprietary to Abcam and/or its suppliers.
-
Positive control
- WB: Human fetal heart lysate; HepG2 whole cell lysate; Mouse and rat heart lysates. IHC-P: Human hepatocellular carcinoma, Human cervix carcinoma, mouse kidney and rat cardiac muscle tissues. ICC/IF: HeLa and HepG2 cells. Flow Cyt: MCF7 cells. IP: Human fetal heart whole cell lysate.
-
General notes
Ab231168 is the carrier-free version of ab202554. This format is designed for use in antibody labeling, including fluorochromes, metal isotopes, oligonucleotides, enzymes.
Our carrier-free formats are supplied in a buffer free of BSA, sodium azide and glycerol for higher conjugation efficiency.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with
ab231168 is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm.
Maxpar® is a trademark of Fluidigm Canada Inc.
Properties
-
Form
Liquid -
Storage instructions
Shipped at 4°C. Store at +4°C. Do Not Freeze. -
Storage buffer
pH: 7.2
Constituent: PBS -
Carrier free
Yes -
Concentration information loading...
-
Purity
Protein A purified -
Clonality
Monoclonal -
Clone number
EPR9442(ABC) -
Isotype
IgG -
Research areas
Images
-
Immunofluorescent analysis of 4% paraformaldehyde-fixed, 0.1% Triton X-100 permeabilized HepG2 (Human liver hepatocellular carcinoma) cells labeling COX IV with ab202554 at 1/1000 dilution, followed by Goat anti-rabbit IgG (Alexa Fluor® 488) (ab150077) secondary antibody at 1/500 dilution (green).
Cytoplasmic staining on HepG2 cells is observed.
The nuclear counter stain is DAPI (blue).
Tubulin is detected with ab7291 (anti-Tubulin mouse mAb) at 1/1000 dilution and ab150120 (AlexaFluor®594 Goat anti-Mouse secondary) at 1/500 dilution (red).
The negative controls are as follows:
-ve control 1: ab202554 at 1/1000 dilution followed by ab150120 (AlexaFluor®594 Goat anti-Mouse secondary) at 1/500 dilution.
-ve control 2: ab7291 (anti-Tubulin mouse mAb) at 1/1000 dilution followed by ab150077 (Alexa Fluor®488 Goat Anti-Rabbit IgG H&L) at 1/500 dilution.This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab202554).
-
Immunohistochemical analysis of paraffin-embedded Human cervix carcinoma tissue labeling COX IV with ab202554 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) secondary antibody at 1/500 dilution.
Cytoplasmic staining on Human cervix carcinoma tissue is observed. Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab202554).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded Mouse kidney tissue labeling COX IV with ab202554 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) secondary antibody at 1/500 dilution.
Cytoplasmic staining on mouse kidney tissue is observed. Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab202554).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded Rat cardiac muscle tissue labeling COX IV with ab202554 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) secondary antibody at 1/500 dilution.
Cytoplasmic staining on Human cervix carcinoma tissue is observed.
Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab202554).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Flow cytometric analysis of 2% paraformaldehyde-fixed MCF7 (Human breast adenocarcinoma cell line) cells labeling COX IV with ab202554 at 1/20 dilution (red) compared with a rabbit monoclonal IgG isotype control (ab172730; black) and an unlabelled control (cells without incubation with primary antibody and secondary antibody; blue). Goat anti rabbit IgG (FITC) at 1/150 dilution was used as the secondary antibody.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab202554).
-
COX IV was immunoprecipitated from 1mg of Human fetal heart whole cell lysate with ab202554 at 1/20 dilution.
Western blot was performed from the immunoprecipitate using ab202554 at 1/1000 dilution.
VeriBlot for IP Detection Reagent (HRP) (ab131366) was used for detection at 1/1500 dilution.
Lane 1: Human fetal heart whole cell lysate 10 µg (Input).
Lane 2: ab202554 IP in Human fetal heart whole cell lysate.
Lane 3: Rabbit monoclonal IgG (ab172730) instead of ab202554 in Human fetal heart whole cell lysate.
Blocking and dilution buffer and concentration: 5% NFDM/TBST.Exposure time: 3 seconds.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab202554).
-
This IHC data was generated using the same anti-COX IV antibody clone, EPR9442(ABC), in a different buffer formulation (cat# ab202554).
Immunohistochemical analysis of paraffin-embedded Human hepatocellular carcinoma tissue labeling COX IV with ab202554 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) secondary antibody at 1/500 dilution.
Cytoplasmic staining on Human hepatocellular carcinoma tissue is observed.
Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
This ICC data was generated using the same anti-COX IV antibody clone, EPR9442(ABC), in a different buffer formulation (cat# ab202554).
Immunofluorescent analysis of 4% paraformaldehyde-fixed, 0.1% Triton X-100 permeabilized HeLa (Human epithelial cells from cervix adenocarcinoma) cells labeling COX IV with ab202554 at 1/1000 dilution, followed by Goat anti-rabbit IgG (Alexa Fluor® 488) (ab150077) secondary antibody at 1/500 dilution (green).
Cytoplasmic staining on HeLa cells is observed.
The nuclear counter stain is DAPI (blue).
Tubulin is detected with ab7291 (anti-Tubulin mouse mAb) at 1/1000 dilution and ab150120 (AlexaFluor®594 Goat anti-Mouse secondary) at 1/500 dilution (red).
The negative controls are as follows:
-ve control 1: ab202554 at 1/1000 dilution followed by ab150120 (AlexaFluor®594 Goat anti-Mouse secondary) at 1/500 dilution.
-ve control 2: ab7291 (anti-Tubulin mouse mAb) at 1/1000 dilution followed by ab150077 (Alexa Fluor®488 Goat Anti-Rabbit IgG H&L) at 1/500 dilution. -