Call: +7 771 977 66 65, +7 705 421 2277
Sign in or Register
My basket

Astana Biomed Group, an authorized Abcam distributor in Central Asia

Abiomed homepage

  • Categories
    Signal Transduction
    Cancer
    Epigenetics and Nuclear Signaling
    Immunology
    Cell Biology
    Cardiovascular
    Neuroscience
    Tags & Cell Markers
    Kits/ Lysates/ Other
    Developmental Biology
    Microbiology
    Biochemicals
    Secondary antibodies
    Isotype/Loading Controls
    Antibody Arrays
  • About us
  • Partners
  • Contact
    Address

    Saryarka 32, 18, 010000, Astana city, Kazakhstan

    Telephone +7 771 977 66 65, +7 705 421 2277

    Email

    laboratory@ctlab.kz, orders@abiomed.kz

Back to category
Signal Transduction Metabolism Mitochondrial

Glutathione Reductase (GR) Assay Kit (ab83461)

Price and availability

365 193 ₸

Availability

Order now and get it on Thursday February 25, 2021

Glutathione Reductase (GR) Assay Kit (ab83461)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)

Key features and details

  • Assay type: Enzyme activity
  • Detection method: Colorimetric
  • Platform: Microplate reader
  • Assay time: 40 min
  • Sample type: Cell Lysate, Other biological fluids, Plasma, Serum, Tissue Extracts, Urine
  • Sensitivity: 0.1 mU/ml

You may also be interested in

Product image
Anti-AFG3L2 antibody (ab154990)
Product image
Anti-HLCS antibody (ab251715)
Product image
Anti-DMPO Nitrone Adduct antibody (ab23702)
Product image
Anti-HAX1 antibody (ab78939)

Overview

  • Product name

    Glutathione Reductase (GR) Assay Kit
  • Detection method

    Colorimetric
  • Sample type

    Urine, Serum, Plasma, Other biological fluids, Tissue Extracts, Cell Lysate
  • Assay type

    Enzyme activity
  • Sensitivity

    > 0.1 mU/ml
  • Range

    0.1 mU/ml - 40 mU/ml
  • Assay time

    0h 40m
  • Product overview

    Glutathione Reductase Assay Kit (ab83461) is a highly sensitive, simple, direct and HTS-ready colorimetric assay for measuring GR activity in biological samples. In the assay, GR reduces GSSG to GSH, which reacts with 5, 5'-Dithiobis (2-nitrobenzoic acid) (DTNB) to generate TNB2- (yellow color, λmax = 405 nm). The assay can detect 0.1-40 mU/ml GR in various samples.

  • Notes

    Glutathione Reductase (GR, EC 1.8.1.7) catalyzes the NADPH-dependent reduction of oxidized glutathione (GSSG) to reduced glutathione (GSH), which plays an important role in the GSH redox cycle that maintains adequate levels of reduced GSH. A high GSH/GSSG ratio is essential for protection against oxidative stress.

    Related products

    Review the oxidative stress marker and assay guide to learn about more assays for oxidative stress.

  • Platform

    Microplate reader

Properties

  • Storage instructions

    Store at -20°C. Please refer to protocols.
  • Components Identifier 200 tests
    Catalase (lyophilized) Clear 1 x 1ng
    DTNB (lyophilized) Red 1 vial
    GR Assay Buffer NM 1 x 100ml
    GR Positive Control (10 mU; lyophilized) Green 1 vial
    GSSG (lyophilized) Yellow 1 vial
    Hydrogen peroxide Orange 1 x 1ml
    NADPH-GNERAT™ (lyophilized) Blue 2 vials
    TNB Standard (2.5 µmol) Brown 1 x 1ng
  • Research areas

    • Signal Transduction
    • Metabolism
    • Mitochondrial
    • Cell Biology
    • Other Antibodies
    • Oxidative Stress
    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Other Metabolism Assay
    • Kits/ Lysates/ Other
    • Kits
    • Cell Signaling Kits
    • Coenzyme and Cofactor Kits
    • Kits/ Lysates/ Other
    • Kits
    • Cell Damage Kits
    • Oxidative stress
    • Metabolism
    • Pathways and Processes
    • Mitochondrial Metabolism
    • Mitochondrial markers
    • Metabolism
    • Pathways and Processes
    • Redox metabolism
    • Antioxidants
  • Relevance

    Glutathione Reductase (GR, EC 1.8.1.7) catalyzes the NADPH-dependent reduction of oxidized glutathione (GSSG) to reduced glutathione (GSH), which plays an important role in the GSH redox cycle that maintains adequate levels of reduced GSH. A high GSH/GSSG ratio is essential for protection against oxidative stress.
  • Cellular localization

    Cytoplasmic and Mitochondrial
  • Alternative names

    • EC 1.8.1.7
    • Glutathione reductase mitochondrial
    • GR
    • GSR
    • MGC78522
    see all

Images

  • Functional Studies - Glutathione Reductase (GR) Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase (GR) Assay Kit (ab83461) Cao, Zeyu et al., Scientific reports?vol. 7,1 16278., Fig 5, doi:10.1038/s41598-017-16446-7
    ICAC decreased the ROS level induced by EV71 infection via modulating the antioxidant enzymes involved in GSH metabolism. Infected (100 TCID50 EV71) Vero cells were treated with medium or 100 µM ICAC for 12 h. Uninfected cells were used as the control group. The antioxidant enzymes activities of the Vero cells were detected (n = 3). All results were expressed as the means ± SEs. Asterisks indicate that the data significantly differ from the EV71 group at the P
  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)

    Glutathione reductase measured in mouse tissue lysates showing activity (mU) per mg of extracted protein (T1=2 min; T2=30 min).

  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)

    Glutathione reductase measured in cell lysates (mU) per 106 cells (T1=2 min; T2=30 min)

  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)

    Glutathione reductase measured in human plasma and serum (T1=2 min; T2=30 min) showing activity (mU) per ml of tested sample. No activity was detected in saliva or urine.

  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Glutathione Reductase assay time line using ab83461.
  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    TNB Standard Curve using ab83461.
  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)

    Glutathione reductase measured in mouse tissue lysates showing activity (mU) per mg of extracted protein (T1=2 min; T2=30 min).

  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)

    Glutathione reductase measured in cell lysates (mU) per 106 cells (T1=2 min; T2=30 min)

  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)

    Glutathione reductase measured in human plasma and serum (T1=2 min; T2=30 min) showing activity (mU) per ml of tested sample. No activity was detected in saliva or urine.

  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Glutathione Reductase assay time line using ab83461.
  • Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    Functional Studies - Glutathione Reductase Assay Kit (ab83461)
    TNB Standard Curve using ab83461.
  • Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
    For licensing inquiries, please contact partnerships@abcam.com

    Clear all

    Recently viewed products

    •  
    • Product image

      Anti-ABCE1 antibody [EPR15373(B)] - C-terminal (ab185548)

    •  
    • Product image

      Anti-eEF1A1/EF-Tu antibody [EPR9471] - BSA and Azide free (ab240142)

    •  
    • Product image

      Anti-Integrin alpha 9 antibody [EPR9722] - BSA and Azide free (ab240116)

    •  
    • Product image

      Anti-Lysophospholipase 1/LPL-I antibody [EPR3667] - BSA and Azide free (ab239901)

    •  
    • Product image

      Recombinant human Eotaxin protein (Active) (ab243753)

    •  
    • Product image

      Complex IV Immunocapture Kit (ab109801)

    Get resources and offers direct to your inbox Sign up
    © 2021 Astana Biomed Group LLP. All rights reserved.