Anti-Mre11 antibody [EPR21027] - BSA and Azide free (ab230381)
Key features and details
- Produced recombinantly (animal-free) for high batch-to-batch consistency and long term security of supply
- Rabbit monoclonal [EPR21027] to Mre11 - BSA and Azide free
- Suitable for: WB, IHC-P, ChIP, Flow Cyt (Intra)
- Reacts with: Mouse, Rat, Human
Overview
-
Product name
Anti-Mre11 antibody [EPR21027] - BSA and Azide free
See all Mre11 primary antibodies -
Description
Rabbit monoclonal [EPR21027] to Mre11 - BSA and Azide free -
Host species
Rabbit -
Tested applications
Suitable for: WB, IHC-P, ChIP, Flow Cyt (Intra)more details -
Species reactivity
Reacts with: Mouse, Rat, Human -
Immunogen
Recombinant fragment. This information is proprietary to Abcam and/or its suppliers.
-
Positive control
- IHC-P: Human colon tissue.
-
General notes
ab230381 is the carrier-free version of ab208020.
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. The carrier-free buffer and high concentration allow for increased conjugation efficiency.
This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free production
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Properties
-
Form
Liquid -
Storage instructions
Shipped at 4°C. Store at +4°C. Do Not Freeze. -
Storage buffer
pH: 7.2
Constituent: PBS -
Carrier free
Yes -
Concentration information loading...
-
Purity
Protein A purified -
Clonality
Monoclonal -
Clone number
EPR21027 -
Isotype
IgG -
Research areas
Images
-
Chromatin was prepared from non-treated HeLa cells or HeLa cells treated with 1% Methyl methanesulfonate for 1 hour according to the Abcam X-ChIP protocol. Cells were fixed with formaldehyde for 10 minutes. The ChIP was performed with 25 µg of chromatin, 5 µg of ab208020 (blue), and 20 µL of protein A/G sepharose beads slurry (10 µL of sepharose A beads + 10 µL of sepharose G beads). 5 μg of rabbit normal IgG was added to the beads control (yellow). The immunoprecipitated DNA was quantified by real time PCR (Sybr green approach).
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208020).
-
Flow cytometric analysis of 4% paraformaldehyde-fixed, 90% methanol permeabilized K562 (Human human chronic myelogenous leukemia cell line from bone marrow) cell line labeling Mre11 with ab208020 at 1/500 dilution (red) compared with a Rabbit IgG, monoclonal [EPR25A] - Isotype Control (ab172730) (black) and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (blue). Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) at 1/2000 dilution was used as the secondary antibody.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208020).
-
Immunohistochemical analysis of paraffin-embedded rat colon tissue labeling Mre11 with ab208020 at 1/2000 dilution, followed by Rabbit specific IHC polymer detection kit HRP/DAB (ab209101), ready to use. Nuclear staining in rat colon tissue is observed (PMID: 28357369). Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Rabbit specific IHC polymer detection kit HRP/DAB (ab209101), ready to use.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208020).
Heat mediated antigen retrieval was performed before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded mouse testis tissue labeling Mre11 with ab208020 at 1/2000 dilution, followed by Rabbit specific IHC polymer detection kit HRP/DAB (ab209101), ready to use. Nuclear staining in mouse testis is observed (PMID: 10508516). Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Rabbit specific IHC polymer detection kit HRP/DAB (ab209101), ready to use.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208020).
Heat mediated antigen retrieval was performed before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded human endometrial carcinoma tissue labeling Mre11 with ab208020 at 1/2000 dilution, followed by Rabbit specific IHC polymer detection kit HRP/DAB (ab209101), ready to use. Nuclear staining in human endometrial carcinoma is observed (PMID: 24927325). Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Rabbit specific IHC polymer detection kit HRP/DAB (ab209101), ready to use.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208020).
Heat mediated antigen retrieval was performed before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded human colon tissue labeling Mre11 with ab208020 at 1/2000 dilution, followed by Rabbit specific IHC polymer detection kit HRP/DAB (ab209101), ready to use. Nuclear staining in human colon tissue is observed (PMID: 25447316). Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Rabbit specific IHC polymer detection kit HRP/DAB (ab209101), ready to use.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab230381).
Heat mediated antigen retrieval was performed before commencing with IHC staining protocol.
-