Call: +7 771 977 66 65, +7 705 421 2277
Sign in or Register
My basket

Astana Biomed Group, an authorized Abcam distributor in Central Asia

Abiomed homepage

  • Categories
    Signal Transduction
    Cancer
    Epigenetics and Nuclear Signaling
    Immunology
    Cell Biology
    Cardiovascular
    Neuroscience
    Tags & Cell Markers
    Kits/ Lysates/ Other
    Developmental Biology
    Microbiology
    Biochemicals
    Secondary antibodies
    Isotype/Loading Controls
    Antibody Arrays
  • About us
  • Partners
  • Contact
    Address

    Saryarka 32, 18, 010000, Astana city, Kazakhstan

    Telephone +7 771 977 66 65, +7 705 421 2277

    Email

    laboratory@ctlab.kz, orders@abiomed.kz

Back to category
Microbiology Organism Virus RNA Virus ssRNA positive strand virus SARS Coronavirus

SARS-CoV-2 IgG ELISA Kit (ab275300)

Key features and details

  • Sample type: Cit plasma, EDTA Plasma, Lithium Heparin Plasma, Serum
  • Detection method: Colorimetric
  • Assay type: Semi-quantitative

You may also be interested in

Product image
Recombinant Human coronavirus SARS-COV-2 Nsp1 protein (His tag) (ab277123)
Product image
Anti-SARS spike glycoprotein antibody [3A2] - Coronavirus (ab272420)
Product image
Anti-SARS-CoV-2 Spike Glycoprotein S1 antibody [HL1] - BSA and Azide free (ab281307)
Product image
Recombinant Human coronavirus SARS-CoV-2 nucleocapsid protein (His tag) (ab273530)

Overview

  • Product name

    SARS-CoV-2 IgG ELISA Kit
    See all SARS-CoV-2 Spike Glycoprotein S1 kits
  • Detection method

    Colorimetric
  • Sample type

    Serum, EDTA Plasma, Cit plasma, Lithium Heparin Plasma
  • Assay type

    Semi-quantitative
  • Assay duration

    Multiple steps standard assay
  • Product overview

    SARS-CoV-2 IgG ELISA Kit (ab275300) is an Enzyme-Linked Immunosorbent Assay (ELISA) intended for semi-quantitative detection of IgG antibodies to SARS-CoV-2 in human serum or plasma collected in potassium EDTA, sodium citrate or lithium heparin.


    This kit is intended for use as an aid in identifying individuals with an adaptive immune response to SARS-CoV-2, indicating recent or prior infection. Understanding the timing, duration and effectiveness of humoral immune responses in individuals previously infected with SARS-CoV-2 will be important for conducting vaccine and epidemiological research. At this time, it is unknown for how long antibodies persist following infection and if the presence of antibodies confers protective immunity.


    Results are for the detection of SARS-CoV-2 antibodies. IgG antibodies to SARS-CoV-2 are generally detectable in blood several days after initial infection, although the duration of time antibodies are present post-infection is not well characterized. Individuals may have detectable virus present for several weeks following seroconversion.


    The sensitivity of SARS-CoV-2 IgG ELISA early after infection is unknown. Negative results do not preclude acute SARS-CoV-2 infection.


    False positive results for SARS-CoV-2 IgG ELISA may occur due to cross-reactivity from pre-existing antibodies to SARS-CoV 1 or other possible causes.

  • Notes

    This kit provides for an indirect ELISA, in which a recombinant receptor binding domain (RBD) of the Spike1 protein of SARS-CoV 2 is coated on the wells of the microtiter plate. Antibodies to SARS-CoV-2 RBD when present in the test sample bind specifically to the RBD protein. After sample binding, unbound proteins and molecules are washed off, and a HRP-conjugated detection antibody is added to the wells to bind to the captured anti-SARS-CoV2 IgG antibodies.  The chromogenic substrate TMB (3,3’,5,5’tetramethylbenzidine) is then added. This reaction produces a blue product, which turns yellow when the reaction is terminated by addition of dilute sulfuric acid. The absorbance of the yellow product at 450 nm, corrected for plate imperfections by subtracting the absorbance at 570 nm, is proportional to the amount of RBD-specific anti-SARS-CoV-2 IgG present in the sample.

    After determining that the values for the Positive Control and Negative Control are valid and acceptable by comparing them to the value for the Calibrator, values for samples are compared to the Calibrator to generate a ratio. Ratios above a cutoff indicate positive samples and values below a cutoff indicate negative samples.

  • Platform

    Pre-coated microplate (12 x 8 well strips)

Properties

  • Storage instructions

    Store at +4°C. Please refer to protocols.
  • Components 1 x 96 tests
    96 well Precoated SARS-CoV-2 S1-RBD plate 1 unit
    Assay Dilution Buffer (ready to use) 1 vial
    Calibrator:  Recombinant Human anti-RBD IgG antibody (ready to use) 1 vial
    Detection Antibody: Goat Anti-Human IgG-Fc antibody – HRP conjugated (ready to use) 1 vial
    Negative Control: Dilute normal human serum (ready to use) 1 vial
    One Component TMB substrate: TMB/Hydrogen Peroxide (ready to use) 1 vial
    Positive Control:  Recombinant Human anti-RBD IgG (ready to use) 1 vial
    Sealing Tape 3 units
    Stop solution (0.18 M Sulfuric Acid; ready to use) 1 vial
    TNT Wash Buffer packet for reconstitution 1 unit
  • Research areas

    • Microbiology
    • Organism
    • Virus
    • RNA Virus
    • ssRNA positive strand virus
    • SARS Coronavirus

Images

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Clear all

Recently viewed products

  •  
  • Product image

    Anti-Histone H2B (acetyl K20) antibody [EPR859] - BSA and Azide free (ab240198)

  •  
  • Product image

    Recombinant human PAI1 (mutated N150H + K154T + Q319L + M354I) protein (ab92969)

  •  
  • Recombinant mouse GRO gamma protein (ab203719)

  •  
  • Product image

    Recombinant Mouse ENO1 protein (His tag) (ab235075)

  •  
  • BHHCT, Fluorescent sensitizer for Eu<sup>3+</sup>- labelling (ab145314)

Get resources and offers direct to your inbox Sign up
© 2021 Astana Biomed Group LLP. All rights reserved.