Prestained Protein Ladder – Mid-range molecular weight (10 - 180 kDa) (ab116027)
Overview
-
Product name
Prestained Protein Ladder – Mid-range molecular weight (10 - 180 kDa)
See all Prestained Protein Ladder reagents -
Description
Prestained Protein Ladder - Mid-range molecular weight (10 - 180 kDa) -
Tested applications
Suitable for: WB, SDS-PAGEmore details -
General notes
Prestained Protein Ladder ab116027 is a three-color protein standard with 10 pre-stained proteins covering a wide range molecular weights for 10 to 180 kDa. Proteins are covalently coupled with a blue chromophore except for two reference bands (one green and one red band at 25 kDa and 75 kDa respectively) when separated on SDS-PAGE (Tris-glycine buffer).
This product was previously called Prism Ultra Protein Ladder (10 - 180 kDa).
This prestained protein ladder is designed for monitoring protein separated during SDS-polyacrylamide gel electrophoresis, verification of Western transfer efficiency on membranes (PVDF, nylon, or nitrocellulose) and for approximate sizing of proteins. The ladder is supplied in gel loading buffer and is ready to use.
Do not heat, dilute, add reducing agent before loading.
Key product features:
- Broad range: 10-180 kDa
- Ready-to-use: Supplied in a loading buffer for direct loading on gels.
- Easy to identify: Includes green ~25 kDa and red ~75kDa reference bands.
- Sharp bands
- Recommended loading: ~2 - 3 µl for western blots
Review other protein ladders in the unstained and prestained protein ladder guide.
Properties
-
Form
Liquid -
Storage instructions
Shipped at 4°C. Store at +4°C short term (1-2 weeks). Store at -20°C long term. -
Storage buffer
pH: 7.5
Constituents: 0.44% Tris citrate/phosphate, 0.02% Urea, 2% Sodium lauryl sulfate, 0.02% DTT, 15% Glycerol -
Concentration information loading...
-
Research areas
-
Alternative names
- Molecular weight marker
- Prism protein ladder
- SDS PAGE protein ladder prestained
see all
Images
-
Gel 1: Tris-Glycine (~4-20%) Gel 2: Bis-Tris (12%) MOPS buffer Gel 3: Bis-Tris (10%) MES buffer Pre-stained molecular weight standards have a differing mobility and as a consequence varying apparent molecular weight when run in distinct SDS-PAGE buffer systems. The variance in pH of alternative buffers affects the charge of the labelled protein standard and its binding capacity for SDS. The apparent molecular weight of this marker has been determined by calibration against an unstained ladder in each electrophoresis condition.
-
Very easy to use protein ladder in the range from 10-180 kDa. Good separation in SDS-PAGE and nice transfer onto nitrocellulose membrane. The gel used was a 10% Tris-Bis gel from life-technologies. the protein ladder was used at 2.5µl per well.