Mouse C Reactive Protein ELISA Kit (ab222511)
Key features and details
- One-wash 90 minute protocol
- Sensitivity: 17 pg/ml
- Range: 156.25 pg/ml - 10000 pg/ml
- Sample type: Cit plasma, EDTA Plasma, Hep Plasma, Serum, Tissue Extracts
- Detection method: Colorimetric
- Assay type: Sandwich (quantitative)
- Reacts with: Mouse
Overview
-
Product name
Mouse C Reactive Protein ELISA Kit
See all C Reactive Protein kits -
Detection method
Colorimetric -
Precision
Intra-assay Sample n Mean SD CV% Serum 5 2.4% Inter-assay Sample n Mean SD CV% Serum 3 2.1% -
Sample type
Serum, Tissue Extracts, Hep Plasma, EDTA Plasma, Cit plasma -
Assay type
Sandwich (quantitative) -
Sensitivity
17 pg/ml -
Range
156.25 pg/ml - 10000 pg/ml -
Recovery
Sample specific recovery Sample type Average % Range Serum 111 109% - 113% Tissue Extracts 115 103% - 122% Hep Plasma 113 110% - 117% EDTA Plasma 107 103% - 109% Cit plasma 108 90% - 117% -
Assay time
1h 30m -
Assay duration
One step assay -
Species reactivity
Reacts with: Mouse
Does not react with: Cow -
Product overview
Mouse C Reactive Protein ELISA Kit (ab222511) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of C Reactive Protein protein in cit plasma, edta plasma, hep plasma, serum, and tissue extracts. It uses our proprietary SimpleStep ELISA® technology. Quantitate Mouse C Reactive Protein with 31 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
- Single-wash protocol reduces assay time to 90 minutes or less
- High sensitivity, specificity and reproducibility from superior antibodies
- Fully validated in biological samples
- 96-wells plate breakable into 12 x 8 wells stripsA 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
-
Notes
C Reactive Protein displays several functions associated with host defense: it promotes agglutination, bacterial capsular swelling, phagocytosis and complement fixation through its calcium-dependent binding to phosphorylcholine. C Reactive Protein can interact with DNA and histones and it may scavenge nuclear material released from damaged circulating cells. C Reactive Protein is secreted; it forms a homopentamer pentaxin (or pentraxin) which have a discoid arrangement of 5 non-covalently bound subunits. C Reactive Protein binds 2 calcium ions per subunit. The concentration of C Reactive Protein in plasma increases greatly during acute phase response to tissue injury, infection or other inflammatory stimuli. It is induced by IL1/interleukin-1and IL6//interleukin-6.
Abcam has not and does not intend to apply for the REACH Authorisation of customers’ uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses. -
Platform
Pre-coated microplate (12 x 8 well strips)
Properties
-
Storage instructions
Please refer to protocols. -
Components 1 x 96 tests 10X Wash Buffer PT (ab206977) 1 x 20ml 50X Cell Extraction Enhancer Solution (ab193971) 1 x 1ml 5X Cell Extraction Buffer PTR (ab193970) 1 x 10ml Antibody Diluent 4BR 1 x 6ml Mouse C Reactive Protein Capture Antibody Concentrate 1 x 22µl Mouse C Reactive Protein Detector Antibody Concentrate 1 x 22µl Mouse C Reactive Protein Lyophilized Recombinant Protein 2 vials Plate Seals 1 unit Sample Diluent NS (ab193972) 1 x 50ml SimpleStep Pre-Coated 96-Well Microplate (ab206978) 1 unit Stop Solution 1 x 12ml TMB Development Solution 1 x 12ml -
Research areas
-
Function
Displays several functions associated with host defense: it promotes agglutination, bacterial capsular swelling, phagocytosis and complement fixation through its calcium-dependent binding to phosphorylcholine. Can interact with DNA and histones and may scavenge nuclear material released from damaged circulating cells. -
Tissue specificity
Found in plasma. -
Sequence similarities
Belongs to the pentaxin family.
Contains 1 pentaxin domain. -
Cellular localization
Secreted. - Information by UniProt
-
Alternative names
- Pentraxin 1, short
- C reactive protein
- C reactive protein pentraxin related
see all -
Database links
- Entrez Gene: 12944 Mouse
- SwissProt: P14847 Mouse
- Unigene: 28767 Mouse
Images
-
SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
-
The C Reactive Protein standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed.
-
The C Reactive Protein standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed.
-
The concentrations of C Reactive Protein were measured in duplicates, interpolated from the C Reactive Protein standard curves and corrected for sample dilution. Undiluted samples are as follows: serum 1:400, plasma (citrate) 1:800, plasma (heparin) 1:400, and plasma (EDTA) 1:1600. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean C Reactive Protein concentration was determined to be 2854 ng/mL in neat serum, 5469 ng/mL in neat plasma (citrate), 3358 ng/mL in neat plasma (heparin), and 7251 ng/mL in neat plasma (EDTA).
-
Based on a 200 μg/mL extract load and mouse heart tissue extract based on a 500 μg/mL extract load. The concentrations of C Reactive Protein were measured in duplicate and interpolated from the C Reactive Protein standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean C Reactive Protein concentration was determined to be 7416 pg/mL in mouse liver tissue extract and 5978 pg/mL in mouse heart tissue extract.
-
To learn more about the advantages of recombinant antibodies see here.