Antibody Diluent (HAMA Blocker) for ELISA (ab193969)
Overview
-
Product name
Antibody Diluent (HAMA Blocker) for ELISA -
Product overview
Antibody Diluent (HAMA Blocker) for ELISA ab193969 is used for sandwich antibody pair based assays that are susceptible to heterophilic antibody interference. This diluent is specially formulated to quantitate your proteins of interest in complex sample types, such as Human serum or Human plasma. Our formulation is shown to alleviate antibody interference due to heterophilic antibodies such as Human Anti-Mouse Antibody (HAMA). Heterophilic antibodies are a common problem in immunoassays such as ELISA, often causing false positive or false negative results. Abcam’s Antibody Diluent (HAMA Blocker) for ELISA is shown to eliminate heterophilic/HAMA interferences without compromising true signal quantitation.
The Antibody Diluent (HAMA Blocker) for ELISA soltuion is also known as Antibody Diluent CPI when included in our SimpleStep ELISA™ kits.
DO NOT FREEZE. Buffer should be stored at +4°C.
-
Notes
Instructions for use
Antibody Diluent (HAMA Blocker) for ELISA comes as a ready to use solution.
Samples should be diluted to within the desired working range of your assay in Antibody Diluent (HAMA Blocker) for ELISA.
Properties
-
Storage instructions
Store at +4°C. Please refer to protocols. -
Components 12 ml 50 ml Antibody Diluent (HAMA blocker) 1 x 12ml 1 x 50ml -
Research areas
Images
-
Example of Heterophilic Antibody Interference in Human Plasma. False positive signals are detected in a sandwich ELISA assay in Heterophilic positive and HAMA positive plasma. This interference was not observed in a control normal human plasma sample. When using both standard blocking buffers and commercially formulated heterophilic blocking buffers (1, 2, 3). Abcam’s Serum and Plasma Assay Diluent outperformed its competitors by eliminating the heterophilic interference or false positive signal. Mean raw absorbance values +/- SD are graphed.
Note on above data:
Commercial Block 1 – strong false positive signal detected in both heterophilic and HAMA positive plasmas.
Commercial Block 2 – Moderate false positive signal detected in heterophilic positive plasma.
Commercial Block 3 – Elevated background (OD ~ 0.2) in all human plasma samples. This high of a background signal negatively affects sensitivity of the assay.
Our Serum and Plasma Assay Diluent – Completely eliminated the heterophilic interference in all human plasma samples tested. (OD ~ 0.08)