Call: +7 771 977 66 65, +7 705 421 2277
Sign in or Register
My basket

Astana Biomed Group, an authorized Abcam distributor in Central Asia

Abiomed homepage

  • Categories
    Signal Transduction
    Cancer
    Epigenetics and Nuclear Signaling
    Immunology
    Cell Biology
    Cardiovascular
    Neuroscience
    Tags & Cell Markers
    Kits/ Lysates/ Other
    Developmental Biology
    Microbiology
    Biochemicals
    Secondary antibodies
    Isotype/Loading Controls
    Antibody Arrays
  • About us
  • Partners
  • Contact
    Address

    Saryarka 32, 18, 010000, Astana city, Kazakhstan

    Telephone +7 771 977 66 65, +7 705 421 2277

    Email

    laboratory@ctlab.kz, orders@abiomed.kz

Back to category

Mouse specific HRP/DAB (ABC) Detection IHC Kit (ab64259)

Price and availability

194 323 ₸

Availability

Order now and get it on Thursday February 25, 2021

Mouse specific HRP/DAB (ABC) Detection IHC Kit (ab64259)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)

You may also be interested in

Tissue Clearing Reagent 1 (ab243300)
1-(5-Isoquinolinesulfonyl)piperazine hydrochloride, PKC inhibitor (ab143831)
Product image
Phospho-CDK1 (T161) ELISA Kit (ab279756)
Product image
Anti-CFDP1 antibody (ab225909)

Overview

  • Product name

    Mouse specific HRP/DAB (ABC) Detection IHC Kit
    See all HRP/DAB detection kit kits
  • Product overview

    Mouse specific HRP/DAB (ABC) IHC Detection Kit ab64259 is a complete kit to detect a primary antibody raised in mouse, using HRP-labeled-streptavidin and a biotinylated anti-mouse secondary antibody.


    It is supplied with a full protocol and with peroxidase and protein blocking reagents, biotinylated secondary antibody, streptavidin-HRP, and DAB substrate.


    In the method:
    - a sample is incubated with an unconjugated primary antibody specific to the target antigen
    - a biotinylated secondary antibody then binds to the primary antibody
    - HRP-labeled streptavidin then binds to the secondary antibody
    - the HRP produces a brown colored substance at the site of primary antibody binding by reacting with DAB.

  • Notes

    For alternative streptavidin-biotin IHC detection kits see:
    - Anti-Mouse / anti-Rabbit HRP-DAB IHC kit ab64264 
    - Anti-Rabbit HRP-DAB IHC Kit ab64261

    For high sensitivity HRP micro-polymer IHC detection kits see:
    - Anti-Mouse / anti-Rabbit HRP/DAB Micro-polymer IHC Kit ab236466
    - Anti-Rabbit HRP-DAB Micro-polymer IHC Kit ab236469

    Alternatively, see HRP-AEC IHC detection kits.

    For staining mouse tissues with mouse antibodies, use mouse-on-mouse polymer kit ab127055.

    Find more kits and reagents for antigen retrieval, blocking, signal amplification, visualization, counterstaining, and mounting in the IHC kits and reagents guide.

  • Tested applications

    Suitable for: IHC-Pmore details

Properties

  • Storage instructions

    Store at +4°C. Please refer to protocols.
  • Components 15 ml
    50x DAB Chromogen 1 x 0.5ml
    Biotinylated goat anti-mouse IgG(H+L) (ab64255) 1 x 15ml
    DAB substrate 1 x 15ml
    Hydrogen Peroxide Block 1 x 15ml
    Protein block 1 x 15ml
    Streptavidin Peroxidase 1 x 15ml
  • Research areas

    • Kits/ Lysates/ Other
    • Kits
    • IHC Kits
    • Kits/ Lysates/ Other
    • Kits
    • IHC tools
    • ABC
  • Relevance

    HRP/DAB detection kit is a immunoenzymatic antigen detection system for immunohistochemistry techniques.

Images

  • Immunohistochemistry - ab64259
    Immunohistochemistry - ab64259 Jovicic N et al., PLoS One 10(7). Fig 6D & E. DOI: 10.1371/journal.pone.0134089. Reproduced under the Creative Commons license https://creativecommons.org/licenses/by/4.0/

    Immunohistochemical analysis staining SMA or CD68 in paraffin embedded mouse liver tissue sections Samples were incubated with anti-α- SMA (ab7817) or anti-CD68 (ab49777). A Mouse specific HRP/DAB (ABC) Detection IHC Kit (AB64259 was used as a stain and Mayer’s hematoxylin was used as a counterstain. Top panel of images staining CD68 and bottom panel staining α-SMA.

  • Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti Mouse HRP/DAB Detection Kit (ab64259)
    Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti Mouse HRP/DAB Detection Kit (ab64259)
    Human colon carcinoma stained with anti p53 antibody using Anti Mouse HRP/DAB Detection Kit (ab64259).

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Alternative products to Mouse specific HRP/DAB (ABC) Detection IHC Kit (ab64259)

  •  
  • Product image

    Mouse and Rabbit Specific HRP/DAB IHC Detection Kit - Micro-polymer (ab236466)

    Applications:

  •  
  • Product image

    Rabbit specific HRP/DAB (ABC) Detection IHC Kit (ab64261)

    Applications:

  •  
  • Product image

    Mouse and Rabbit Specific HRP/DAB (ABC) Detection IHC kit (ab64264)

    Applications:

  •  
  • Product image

    Rabbit specific HRP/DAB Detection IHC Detection Kit - Micro-polymer (ab236469)

    Applications:

Clear all

Recently viewed products

  •  
  • Product image

    Anti-HEXIM2 antibody (ab234979)

  •  
  • Product image

    Cytokine Array – Mouse Cytokine Antibody Array (Membrane, 22 Targets) (ab133993)

  •  
  • Product image

    Anti-PLCZ1 antibody (ab181816)

  •  
  • Product image

    Recombinant Human Lymphotactin/ATAC protein (ab85406)

  •  
  • Product image

    Recombinant Human SPINK4 protein (His tag) (ab276421)

  •  
  • Product image

    Recombinant Staphylococcus aureus PDF protein (Tagged) (ab235870)

Get resources and offers direct to your inbox Sign up
© 2021 Astana Biomed Group LLP. All rights reserved.