Anti-L1CAM antibody [EPR18750] - Low endotoxin, Azide free (ab213611)
Key features and details
- Produced recombinantly (animal-free) for high batch-to-batch consistency and long term security of supply
- Rabbit monoclonal [EPR18750] to L1CAM - Low endotoxin, Azide free
- Suitable for: IHC-P, WB, IP
- Knockout validated
- Reacts with: Mouse, Rat, Human
Overview
-
Product name
Anti-L1CAM antibody [EPR18750] - Low endotoxin, Azide free
See all L1CAM primary antibodies -
Description
Rabbit monoclonal [EPR18750] to L1CAM - Low endotoxin, Azide free -
Host species
Rabbit -
Tested applications
Suitable for: IHC-P, WB, IPmore details -
Species reactivity
Reacts with: Mouse, Rat, Human -
Immunogen
Recombinant fragment. This information is proprietary to Abcam and/or its suppliers.
-
Positive control
- WB: Human fetal brain and cerebellum lysates; HeLa and A-375 whole cell lysates; Rat brain, cerebellum and hippocampus lysates. Mouse cerebellum and brain lysates. IHC-P: Human kidney, Human stomach cancer, mouse cerebrum, mouse colon, rat cerebellum and rat colon tissues. IP: Human cerebellum lysate; Rat brain whole lysate.
-
General notes
ab213611 is a carrier-free antibody designed for use in antibody labeling, including fluorochromes, metal isotopes, oligonucleotides, enzymes.
Our Low endotoxin, azide-free formats have low endotoxin level (≤ 1 EU/ml, determined by the LAL assay) and are free from azide, to achieve consistent experimental results in functional assays.
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free production
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Reproducibility is key to advancing scientific discovery and accelerating scientists’ next breakthrough.
Abcam is leading the way with our range of recombinant antibodies, knockout-validated antibodies and knockout cell lines, all of which support improved reproducibility.
We are also planning to innovate the way in which we present recommended applications and species on our product datasheets, so that only applications & species that have been tested in our own labs, our suppliers or by selected trusted collaborators are covered by our Abpromise™ guarantee.
In preparation for this, we have started to update the applications & species that this product is Abpromise guaranteed for.
We are also updating the applications & species that this product has been “predicted to work with,” however this information is not covered by our Abpromise guarantee.
Applications & species from publications and Abreviews that have not been tested in our own labs or in those of our suppliers are not covered by the Abpromise guarantee.
Please check that this product meets your needs before purchasing. If you have any questions, special requirements or concerns, please send us an inquiry and/or contact our Support team ahead of purchase. Recommended alternatives for this product can be found below, as well as customer reviews and Q&As.
Properties
-
Form
Liquid -
Storage instructions
Shipped at 4°C. Store at +4°C. Do Not Freeze. -
Storage buffer
pH: 7.2
Constituent: PBS -
Carrier free
Yes -
Concentration information loading...
-
Purity
Protein A purified -
Clonality
Monoclonal -
Clone number
EPR18750 -
Isotype
IgG -
Research areas
Images
-
All lanes : Anti-L1CAM antibody [EPR18750] (ab208155) at 1/1000 dilution
Lane 1 : Wild-type HeLa cell lysate
Lane 2 : L1CAM knockout HeLa cell lysate
Lysates/proteins at 20 µg per lane.
Performed under reducing conditions.
Predicted band size: 140 kDa
Observed band size: 220 kDa why is the actual band size different from the predicted?This data was developed using the same antibody clone in a different buffer formulation (ab208155).
Lanes 1 - 2: Merged signal (red and green). Green - ab208155 observed at 220 kDa. Red - loading control, ab130007 observed at 125 kDa.
ab208155 was shown to react with L1CAM in wild-type HeLa. Loss of signal was observed when knockout cell line ab255401 (knockout cell lysate ab263786) was used. Wild-type and L1CAM knockout samples were subjected to SDS-PAGE. ab208155 and Anti-Vinculin antibody [VIN-54] (ab130007) were incubated overnight at 4^°C at 1 in 1000 dilution and 1 in 20000 dilution respectively. Blots were developed with Goat anti-Rabbit IgG H&L (IRDye® 800CW) preadsorbed (ab216773) and Goat anti-Mouse IgG H&L (IRDye® 680RD) preadsorbed (ab216776) secondary antibodies at 1 in 20000 dilution for 1 hour at room temperature before imaging.
-
Immunohistochemical analysis of paraffin-embedded Human kidney tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Membrane staining on a part of Human kidney tubules is observed.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded Human liver tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Negative staining on the Human liver.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].
Counter stained with Hematoxylin.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded Mouse colon tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Mainly membrane staining on the nerve tract of mouse colon is observed.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded Mouse testis tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Negative staining on the mouse testis.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].Counter stained with Hematoxylin.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded Rat cerebellum tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Cytoplasm staining on the molecular layer of the rat cerebellar cortex is observed.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded Rat colon tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Cytoplasm staining on the nerve tract of the rat colon is observed.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
Immunohistochemical analysis of paraffin-embedded Rat skeletal muscle tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Negative staining on the rat skeletal muscle.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is ab97051 at 1/500 dilution.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
L1CAM was immunoprecipitated from 1mg of Human cerebellum lysate with ab208155 at 1/40 dilution. Western blot was performed from the immunoprecipitate using ab208155 at 1/1000 dilution. VeriBlot for IP Detection Reagent (HRP) (ab131366), was used for detection at 1/10,000 dilution.
Lane 1: Human cerebellum lysate 10µg (Input).
Lane 2: ab208155 IP in Human cerebellum lysate.
Lane 3: Rabbit monoclonal IgG (ab172730) instead of ab208155 in Human cerebellum lysate.
Blocking and dilution buffer and concentration: 5% NFDM/TBST.
Exposure time: 3 minutes.This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
-
L1CAM was immunoprecipitated from 1mg of Rat brain whole cell lysate with ab208155 at 1/40 dilution. Western blot was performed from the immunoprecipitate using ab208155 at 1/1000 dilution. VeriBlot for IP Detection Reagent (HRP) (ab131366), was used for detection at 1/10,000 dilution.
Lane 1: Rat brain whole cell lysate 10µg (Input).
Lane 2: ab208155 IP in Rat brain whole cell lysate.
Lane 3: Rabbit monoclonal IgG (ab172730) instead of ab208155 in Rat brain whole cell lysate.
Blocking and dilution buffer and concentration: 5% NFDM/TBST.
Exposure time: 3 minutes.This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab208155).
-
This IHC data was generated using the same anti-L1CAM antibody clone, EPR18750, in a different buffer formulation (cat# ab208155).
Immunohistochemical analysis of paraffin-embedded Mouse cerebrum tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Cytoplasm staining on the mouse cerebrum is observed.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-
This IHC data was generated using the same anti-L1CAM antibody clone, EPR18750, in a different buffer formulation (cat# ab208155).
Immunohistochemical analysis of paraffin-embedded Human stomach cancer tissue labeling L1CAM with ab208155 at 1/500 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.
Membrane staining on the tumor cells of Human stomach cancer is observed.
L1CAM specific staining most abundant on nervous system, distal kidney tubules, and tumor cells. [PMID: 16867862, PMID: 20044598].Counter stained with Hematoxylin.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/500 dilution.Heat mediated antigen retrieval was performed with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
-