Anti-Asialoglycoprotein Receptor 1/HL-1 antibody [EPR22642-17] - BSA and Azide free (ab256509)
Key features and details
- Produced recombinantly (animal-free) for high batch-to-batch consistency and long term security of supply
- Rabbit monoclonal [EPR22642-17] to Asialoglycoprotein Receptor 1/HL-1 - BSA and Azide free
- Suitable for: WB, ICC/IF, IHC-P, Flow Cyt, IP
- Reacts with: Human
Overview
-
Product name
Anti-Asialoglycoprotein Receptor 1/HL-1 antibody [EPR22642-17] - BSA and Azide free
See all Asialoglycoprotein Receptor 1/HL-1 primary antibodies -
Description
Rabbit monoclonal [EPR22642-17] to Asialoglycoprotein Receptor 1/HL-1 - BSA and Azide free -
Host species
Rabbit -
Tested applications
Suitable for: WB, ICC/IF, IHC-P, Flow Cyt, IPmore details -
Species reactivity
Reacts with: Human -
Immunogen
Recombinant fragment. This information is proprietary to Abcam and/or its suppliers.
-
Positive control
- IHC-P: Human liver and liver cancer tissue. ICC/IF: HepG2 cells. Flow: HepG2 cells. IP: HepG2 whole cell lysate.
-
General notes
ab256509 is the carrier-free version of ab254262.
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. The carrier-free buffer and high concentration allow for increased conjugation efficiency.
This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free production
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Properties
-
Form
Liquid -
Storage instructions
Shipped at 4°C. Store at +4°C. Do Not Freeze. -
Storage buffer
pH: 7.2
Constituent: PBS -
Carrier free
Yes -
Concentration information loading...
-
Purity
Protein A purified -
Clonality
Monoclonal -
Clone number
EPR22642-17 -
Isotype
IgG -
Research areas
Images
-
Asialoglycoprotein Receptor 1/HL-1 antibody was immunoprecipitated from 0.35 mg HepG2 (Human hepatocellular carcinoma epithelial cell) whole cell lysate 10μg with ab254262 at 1/30 dilution (2μg in 0.35mg lysates). Western blot was performed on the immunoprecipitate using ab254262 at 1/1000 dilution. VeriBlot for IP Detection Reagent (HRP) (ab131366) was used as the secondary antibody at 1/5000 dilution.
Lane 1: HepG2 (Human hepatocellular carcinoma epithelial cell) whole cell lysate 10μg
Lane 2: ab254262 IP in HepG2 whole cell lysate
Lane 3: Rabbit monoclonal IgG (ab172730) instead of ab254262 in HepG2 whole cell lysate.
Blocking and dilution buffer and concentration: 5% NFDM/TBST.
Exposure time: 7 seconds.
The band at around 100kDa is described as dimers (PMID: 7663158).
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254262).
-
Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% TritonX-100 permeabilized HepG2 (human hepatocellular carcinoma epithelial cell line) cells labelling Asialoglycoprotein Receptor 1/HL-1 antibody with ab254262 at 1/100 dilution, followed by ab150077 AlexaFluor®488 Goat anti-Rabbit secondary antibody at 1/1000 dilution (Green). Confocal image showing membranous and weak cytoplasmic staining in HepG2 cellsis observed. ab195889 Anti-alpha Tubulin antibody [DM1A] - Microtubule Marker (Alexa Fluor® 594) was used to counterstain tubulin at 1/200 dilution (Red). The Nuclear counterstain was DAPI (Blue).
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is ab150077 AlexaFluor®488 Goat anti-Rabbit secondary at 1/1000 dilution.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254262).
-
Immunohistochemical analysis of paraffin-embedded Human liver tissue labeling Asialoglycoprotein Receptor 1/HL-1 antibody with ab254262 at 1/1000 dilution (0.5 μg/ml) followed by a Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining in human liver (PMID:23979840, 26422581, 27241665) is observed.
The section was incubated with ab254262 for 15 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 20 mins.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254262).
-
Immunohistochemical analysis of paraffin-embedded Human liver cancer tissue labeling Asialoglycoprotein Receptor 1/HL-1 antibody with ab254262 at 1/1000 dilution (0.5 μg/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining in human liver cancer (PMID:23979840,26422581,27241665) is observed.
The section was incubated with ab254262 for 15 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 20 mins.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254262).
-
Negative control: No staining in human colon (PMID:23979840).
Immunohistochemical analysis of paraffin-embedded Human colon tissue labeling Asialoglycoprotein Receptor 1/HL-1 antibody with ab254262 at 1/1000 dilution (0.5 μg/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
The section was incubated with ab254262 for 15 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 20 mins.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254262).
-
Negative control: No staining in human cerebrum (PMID:23979840)
Immunohistochemical analysis of paraffin-embedded Human cerebrum tissue labeling Asialoglycoprotein Receptor 1/HL-1 antibody with ab254262 at 1/1000 dilution (0.5 μg/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
The section was incubated with ab254262 for 15 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 20 mins.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254262).
-
Flow cytometric analysis of HepG2 (Human hepatocellular carcinoma epithelial cell line) cells labelling Asialoglycoprotein Receptor 1/HL-1 antibody with ab254262 at 1/500 dilution (Red) compared with a Rabbit monoclonal IgG (ab172730, Black) isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue). Goat anti rabbit IgG (Alexa Fluor® 488, ab150077) at 1/2000 dilution was used as the secondary antibody. Gated on viable cells.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254262).
-