Mouse IL-28A ELISA Kit (ab208989)
Key features and details
- One-wash 90 minute protocol
- Sensitivity: 2.4 pg/ml
- Range: 15.63 pg/ml - 1000 pg/ml
- Sample type: Cell culture supernatant, Cit plasma, EDTA Plasma, Serum
- Detection method: Colorimetric
- Assay type: Sandwich (quantitative)
- Reacts with: Mouse
Overview
-
Product name
Mouse IL-28A ELISA Kit
See all IL-28A kits -
Detection method
Colorimetric -
Precision
Intra-assay Sample n Mean SD CV% Serum 5 6.7% Inter-assay Sample n Mean SD CV% Serum 3 4.1% -
Sample type
Cell culture supernatant, Serum, EDTA Plasma, Cit plasma -
Assay type
Sandwich (quantitative) -
Sensitivity
2.4 pg/ml -
Range
15.63 pg/ml - 1000 pg/ml -
Recovery
Sample specific recovery Sample type Average % Range Cell culture supernatant 105 102% - 107% Serum 111 110% - 112% Cell culture media 108 106% - 108% EDTA Plasma 106 106% - 106% Cit plasma 111 109% - 112% -
Assay time
1h 30m -
Assay duration
One step assay -
Species reactivity
Reacts with: Mouse -
Product overview
Mouse IL-28A ELISA Kit (ab208989) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of IL-28A protein in cell culture supernatant, cit plasma, edta plasma, and serum. It uses our proprietary SimpleStep ELISA® technology. Quantitate Mouse IL-28A with 2.4 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
- Single-wash protocol reduces assay time to 90 minutes or less
- High sensitivity, specificity and reproducibility from superior antibodies
- Fully validated in biological samples
- 96-wells plate breakable into 12 x 8 wells stripsA 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
-
Notes
IL-28A (Interleukin 28A), also known as IFN-lambda 2 (Interferon-lambda 2), is a class II cytokine receptor ligand with antiviral, antitumor, and immunomodulatory activities.
-
Platform
Microplate (12 x 8 well strips)
Properties
-
Storage instructions
Store at +4°C. Please refer to protocols. -
Components 1 x 96 tests 10X Mouse IL-28A Capture Antibody 1 x 600µl 10X Mouse IL-28A Detector Antibody 1 x 600µl 10X Wash Buffer PT (ab206977) 1 x 20ml Antibody Diluent 5BI 1 x 6ml Mouse IL-28A Lyophilized Recombinant Protein 2 vials Plate Seals 1 unit Sample Diluent NS (ab193972) 1 x 50ml SimpleStep Pre-Coated 96-Well Microplate (ab206978) 1 unit Stop Solution 1 x 12ml TMB Development Solution 1 x 12ml -
Research areas
-
Function
Cytokine with immunomodulatory activity. Up-regulates MHC class I antigen expression. Displays potent antiviral activity. Also displays antitumor activity. Ligand for the heterodimeric class II cytokine receptor composed of IL10RB and IL28RA. The ligand/receptor complex seems to signal through the Jak-STAT pathway. -
Sequence similarities
Belongs to the IL-28/IL-29 family. -
Cellular localization
Secreted. - Information by UniProt
-
Alternative names
- Cytokine ZCYTO20
- IFN-lambda-2
- IFNL2
see all -
Database links
- Entrez Gene: 330496 Mouse
- SwissProt: Q4VK74 Mouse
- Unigene: 454510 Mouse
Images
-
SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
-
Background-subtracted data values (mean +/- SD) are graphed.
-
The concentrations of IL-28A were measured in duplicates, interpolated from the (target) standard curves and corrected for sample dilution. 1X diluted samples are as follows: serum 12.5% and plasma (citrate) 12.5%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).
-
The concentrations of IL-28A were measured in duplicates, interpolated from the (target) standard curves and corrected for sample dilution. 1X diluted samples are as follows: lung cell culture supernatant 25%, and RAW 264.7 cell culture supernatant 25%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).
-
To learn more about the advantages of recombinant antibodies see here.