Key features and details
- One-wash 90 minute protocol
- Sensitivity: 23 pg/ml
- Range: 46.9 pg/ml - 3000 pg/ml
- Sample type: Cell culture extracts, Cell culture supernatant, Cit plasma, EDTA Plasma, Hep Plasma, Serum
- Detection method: Colorimetric
- Assay type: Sandwich (quantitative)
- Reacts with: Human
Overview
-
Product name
Human OX40 ELISA Kit (TNFRSF4)
See all CD134 / OX40L receptor kits -
Detection method
Colorimetric -
Precision
Intra-assay Sample n Mean SD CV% Cell medium 5 3.6% Inter-assay Sample n Mean SD CV% Cell medium 3 4.9% -
Sample type
Cell culture supernatant, Serum, Cell culture extracts, Hep Plasma, EDTA Plasma, Cit plasma -
Assay type
Sandwich (quantitative) -
Sensitivity
23 pg/ml -
Range
46.9 pg/ml - 3000 pg/ml -
Recovery
Sample specific recovery Sample type Average % Range Serum 120 116% - 122% Cell culture extracts 106 102% - 111% Cell culture media 113 112% - 114% Hep Plasma 120 116% - 121% EDTA Plasma 115 112% - 117% Cit plasma 116 113% - 117% -
Assay time
1h 30m -
Assay duration
One step assay -
Species reactivity
Reacts with: Human -
Product overview
Human OX40 ELISA Kit (TNFRSF4) (ab231926) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of OX40 protein in cit plasma, edta plasma, hep plasma, serum, cell culture supernatant, and cell culture extracts. It uses our proprietary SimpleStep ELISA® technology. Quantitate Human OX40 with 23 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
- Single-wash protocol reduces assay time to 90 minutes or less
- High sensitivity, specificity and reproducibility from superior antibodies
- Fully validated in biological samples
- 96-wells plate breakable into 12 x 8 wells stripsA 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
-
Notes
Abcam has not and does not intend to apply for the REACH Authorisation of customers’ uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses. -
Platform
Pre-coated microplate (12 x 8 well strips)
Properties
-
Storage instructions
Store at +4°C. Please refer to protocols. -
Components 1 x 96 tests 10X Human OX40 Capture Antibody 1 x 600µl 10X Human OX40 Detector Antibody 1 x 600µl 10X Wash Buffer PT (ab206977) 1 x 20ml 5X Cell Extraction Buffer PTR (ab193970) 1 x 10ml Antibody Diluent 4BI 1 x 6ml Human OX40 Lyophilized Recombinant Protein 2 vials Plate Seals 1 unit Sample Diluent NS (ab193972) 1 x 12ml SimpleStep Pre-Coated 96-Well Microplate (ab206978) 1 unit Stop Solution 1 x 12ml TMB Development Solution 1 x 12ml -
Research areas
-
Function
Receptor for TNFSF4/OX40L/GP34. -
Sequence similarities
Contains 4 TNFR-Cys repeats. -
Cellular localization
Membrane. - Information by UniProt
-
Alternative names
- ACT 35
- ACT35
- ACT35 antigen
see all -
Database links
- Entrez Gene: 7293 Human
- Omim: 600315 Human
- SwissProt: P43489 Human
- Unigene: 129780 Human
Images
-
SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
-
Background-subtracted data values (mean +/- SD) are graphed.
-
Background-subtracted data values (mean +/- SD) are graphed.
-
The concentrations of OX40 were measured in duplicates, interpolated from the OX40 standard curves and corrected for sample dilution. Undiluted samples are as follows: serum 12.5%, plasma (citrate) 25%, plasma (heparin) 12.5% and plasma (EDTA) 25%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).
Serum from ten individual healthy human female donors was measured in duplicate. No detectable levels of OX40 were measured.
-
The concentrations of OX40 were measured in duplicates, interpolated from the OX40 standard curves and corrected for sample dilution. Undiluted samples are as follows: Stimulated PBMC cell culture supernatant 100%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean OX40 concentration was determined to be 296 pg/mL in Stimulated PBMC cell culture supernatant, and undetectable in unstimulated and media controls.
-
The concentrations of OX40 were measured in duplicate and interpolated from the OX40 standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean OX40 concentration was determined to be 419 pg/mL in Jurkat Cell Extract.
-
To learn more about the advantages of recombinant antibodies see here.