Human IL-8 ELISA Kit, Fluorescent (ab229402)
Key features and details
- One-wash 90 minute protocol
- Sensitivity: 0.45 pg/ml
- Range: 0.49 pg/ml - 2000 pg/ml
- Sample type: Cell culture supernatant, Cit plasma, EDTA Plasma, Hep Plasma, Serum
- Detection method: Fluorescent
- Assay type: Sandwich (quantitative)
- Reacts with: Human
Overview
-
Product name
Human IL-8 ELISA Kit, Fluorescent
See all IL-8 kits -
Detection method
Fluorescent -
Precision
Intra-assay Sample n Mean SD CV% Supernatant 5 1.8% Inter-assay Sample n Mean SD CV% Supernatant 3 7.5% -
Sample type
Cell culture supernatant, Serum, Hep Plasma, EDTA Plasma, Cit plasma -
Assay type
Sandwich (quantitative) -
Sensitivity
0.45 pg/ml -
Range
0.49 pg/ml - 2000 pg/ml -
Recovery
Sample specific recovery Sample type Average % Range Serum 99 93% - 103% Cell culture media 101 98% - 104% Hep Plasma 87 82% - 91% EDTA Plasma 88 84% - 92% Cit plasma 86 83% - 90% -
Assay time
1h 30m -
Assay duration
One step assay -
Species reactivity
Reacts with: Human
Does not react with: Cow -
Product overview
IL-8 in vitro CatchPoint SimpleStep ELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for the quantitative measurement of IL-8 protein in human serum, plasma, and cell culture supernatant.
This CatchPoint SimpleStep ELISA kit has been optimized for Molecular Devices Microplate Readers. Click here for a list of recommended Microplate Readers.
If using a Molecular Devices’ plate reader supported by SoftMax® Pro software, a preconfigured protocol for these CatchPoint SimpleStep ELISA Kits is available with all the protocol and analysis settings at www.softmaxpro.org.The CatchPoint SimpleStep ELISA employs an affinity tag labeled capture antibody and a reporter conjugated detector antibody which immunocapture the sample analyte in solution. This entire complex (capture antibody/analyte/detector antibody) is in turn immobilized via immunoaffinity of an anti-tag antibody coating the well. To perform the assay, samples or standards are added to the wells, followed by the antibody mix. After incubation, the wells are washed to remove unbound material. CatchPoint HRP Development Solution containing the Stoplight Red Substrate is added. During incubation, the substrate is catalyzed by HRP generating a fluorescent product. Signal is generated proportionally to the amount of bound analyte and the intensity is measured in a fluorescence plater reader at 530/570/590 nm Excitation/Cutoff/Emission.
-
Notes
IL-8 is a chemotactic factor that attracts neutrophils, basophils, and T cells, but not monocytes. It is also involved in neutrophil activation. It is released from several cell types in response to an inflammatory stimulus. IL-8(6-77) has a 5-10-fold higher activity on neutrophil activation, IL-8(5-77) has increased activity on neutrophil activation and IL-8(7-77) has a higher affinity to receptors CXCR1 and CXCR2 as compared to IL-8(1-77), respectively
-
Platform
Pre-coated microplate (12 x 8 well strips)
Properties
-
Storage instructions
Store at +4°C. Please refer to protocols. -
Components 1 x 96 tests 100X Stoplight Red Substrate 1 x 120µl 10X Human IL-8 Capture Antibody 1 x 600µl 10X Human IL-8 Detector Antibody 1 x 600µl 10X Wash Buffer PT (ab206977) 1 x 20ml 500X Hydrogen Peroxide (H2O2, 3%) 1 x 50µl Antibody Diluent 4BI 1 x 6ml Human IL-8 Lyophilized Recombinant Protein 2 vials Plate Seals 1 unit Sample Diluent NS (ab193972) 1 x 50ml SimpleStep Pre-Coated Black 96-Well Microplate 1 unit Stoplight Red Substrate Buffer 1 x 12ml -
Research areas
-
Function
IL-8 is a chemotactic factor that attracts neutrophils, basophils, and T-cells, but not monocytes. It is also involved in neutrophil activation. It is released from several cell types in response to an inflammatory stimulus. IL-8(6-77) has a 5-10-fold higher activity on neutrophil activation, IL-8(5-77) has increased activity on neutrophil activation and IL-8(7-77) has a higher affinity to receptors CXCR1 and CXCR2 as compared to IL-8(1-77), respectively. -
Sequence similarities
Belongs to the intercrine alpha (chemokine CxC) family. -
Post-translational
modificationsSeveral N-terminal processed forms are produced by proteolytic cleavage after secretion from at least peripheral blood monocytes, leukcocytes and endothelial cells. In general, IL-8(1-77) is referred to as interleukin-8. IL-8(6-77) is the most promiment form. -
Cellular localization
Secreted. - Information by UniProt
-
Alternative names
- (Ala-IL-8)77
- (Ser-IL-8)72
- 9E3
see all -
Database links
- Entrez Gene: 3576 Human
- Omim: 146930 Human
- SwissProt: P10145 Human
- Unigene: 624 Human
Images
-
SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
-
Background-subtracted data values (mean +/- SD) are graphed.
-
The concentrations of IL-8 were measured in duplicates, interpolated from the IL-8 standard curves and corrected for sample dilution. Undiluted samples are as follows: serum 50%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-8 concentration was determined to be 63.2 pg/mL in serum.
-
The concentrations of IL-8 were measured in duplicates, interpolated from the IL-8 standard curves and corrected for sample dilution. Undiluted samples are as follows: plasma (EDTA) 50%, plasma (citrate) 50%, and plasma (heparin) 50%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).
-
Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-8 concentration was determined to be 61.6 pg/mL with a range of 62 – 174.9 pg/mL; two individuals (Donor #3 and Donor #9) measured below the minimal detectable dose.
-
The concentrations of IL-8 were measured in duplicates, interpolated from the IL-8 standard curves and corrected for sample dilution. Undiluted samples are as follows: unstimulated 1:400 and stimulated 1:400. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). Measured values were interpolated from the IL-8 Standard Curve diluted in Sample Diluent NS and corrected for dilution factor. The mean IL-8 concentration was determined to be 2.2 ng/mL in unstimulated, 119.7ng/mL in stimulated, and undetectable in media.
-
To learn more about the advantages of recombinant antibodies see here.