Call: +7 771 977 66 65, +7 705 421 2277
Sign in or Register
My basket

Astana Biomed Group, an authorized Abcam distributor in Central Asia

Abiomed homepage

  • Categories
    Signal Transduction
    Cancer
    Epigenetics and Nuclear Signaling
    Immunology
    Cell Biology
    Cardiovascular
    Neuroscience
    Tags & Cell Markers
    Kits/ Lysates/ Other
    Developmental Biology
    Microbiology
    Biochemicals
    Secondary antibodies
    Isotype/Loading Controls
    Antibody Arrays
  • About us
  • Partners
  • Contact
    Address

    Saryarka 32, 18, 010000, Astana city, Kazakhstan

    Telephone +7 771 977 66 65, +7 705 421 2277

    Email

    laboratory@ctlab.kz, orders@abiomed.kz

Back to category

Fatty Acid Oxidation Assay Kit (flow cytometry) (ab118183)

Price and availability

314 937 ₸

Availability

Order now and get it on Tuesday March 09, 2021

Fatty Acid Oxidation Assay Kit (flow cytometry) (ab118183)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)
  • ChIP - Anti-Histone H3 antibody - Nuclear Loading Control and ChIP Grade (ab1791)

Key features and details

  • Assay type: Quantitative
  • Detection method: Fluorescent
  • Platform: Flow cytometer
  • Sample type: Adherent cells, Suspension cells

You may also be interested in

Product image
Glycogen Assay Kit (ab65620)
Product image
Anti-FITM1 antibody (ab224422)
Product image
8-Hydroxypyrene-1,3,6-trisulfonic acid trisodium salt (ab275307)
Product image
Anti-DNase gamma antibody (ab152118)

Overview

  • Product name

    Fatty Acid Oxidation Assay Kit (flow cytometry)
    See all Fatty Acid Oxidation kits
  • Detection method

    Fluorescent
  • Sample type

    Adherent cells, Suspension cells
  • Assay type

    Quantitative
  • Product overview

    Fatty Acid Oxidation Assay Kit ab118183 contains antibodies against key enzymes of the mitochondrial fatty acid oxidation pathway for flow cytometry. The assay combines the power of single cell analysis obtained from flow cytometry with the specificity of antibody-based immunostaining to quantify protein levels in cultured cells. Cells are harvested and fixed/permeabilized in suspension, targets of interest are detected indirectly with highly specific well-characterized monoclonal antibodies that are then labeled with fluorescent antibodies


     


    This product was previously called Fatty Acid Oxidation Human Flow Cytometry Kit.

  • Notes

    Spin down the contents of the antibody vials upon receipt of the kit. Store all components upright at 4°C. This kit is stable for at least 6 months from receipt.

    Abcam has not and does not intend to apply for the REACH Authorisation of customers’ uses of products that contain European Authorisation list (Annex XIV) substances.
    It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.

  • Platform

    Flow cytometer

Properties

  • Storage instructions

    Store at +4°C. Please refer to protocols.
  • Components 96 tests
    100X ACADM Primary Antibody 1 x 0.12ml
    100X ACADVL Primary Antibody 1 x 0.12ml
    100X HADHA Primary Antibody 1 x 0.12ml
    100X Normal Mouse IgG 1 x 0.12ml
    100X Triton X-100 1 x 1.25ml
    10X Phosphate Buffered Saline 1 x 100ml
    400X Tween-20 1 x 4ml
    Blocking Solution 1 x 25ml
  • Research areas

    • Cardiovascular
    • Lipids / Lipoproteins
    • Lipid Metabolism
    • Hydrolysis
    • Signal Transduction
    • Metabolism
    • Mitochondrial
    • Signal Transduction
    • Metabolism
    • Lipid metabolism
    • Cardiovascular
    • Lipids / Lipoproteins
    • Fatty Acids
    • Metabolism
    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Fatty Acid Assays
    • Cancer
    • Cancer Metabolism
    • Metabolic signaling pathway
    • Metabolism of lipids and lipoproteins
    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Lipid Metabolism Kits
    • Fatty acids
    • Metabolism
    • Pathways and Processes
    • Mitochondrial Metabolism
    • Mitochondrial markers
    • Metabolism
    • Pathways and Processes
    • Metabolic signaling pathways
    • Lipid and lipoprotein metabolism
    • Lipid metabolism
    • Metabolism
    • Pathways and Processes
    • Metabolic signaling pathways
    • Lipid and lipoprotein metabolism
    • Hydrolysis
    • Metabolism
    • Pathways and Processes
    • Metabolic signaling pathways
    • Lipid and lipoprotein metabolism
    • Fatty acids
    • Metabolism
    • Pathways and Processes
    • Redox metabolism
    • Fatty acid oxidation
  • Alternative names

    • Beta Oxidation
    • Beta-Oxidation

Images

  • Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)
    Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)

    Expression levels of ACADVL was determined in primary fibroblasts by flow cytometry. Blue: control cell line. Red: deficient cell lines extracted from patients with well characterized mutations in each of the enzymes ACADVL:p[N122D]. Black: Background fluorescence was determined with the supplied negative control.

  • Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)
    Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)

    After background subtraction, the ACADVL deficient cell line shows a 93% reduction in the level of the ACADVL protein.

  • Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)
    Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)

    Expression levels of HADHA was determined in primary fibroblasts by flow cytometry. Blue: control cell line. Red: deficient cell lines extracted from patients with well characterized mutations in each of the enzymes HADHB:p[R61H];[R247H]. Black: Background fluorescence was determined with the supplied negative control.

  • Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)
    Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)

    After background subtraction, the LCHAD deficient cell line shows a 50% reduction in the level of the HADHA protein.

  • Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)
    Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)

    Expression levels of ACADM was determined in primary fibroblasts by flow cytometry. Blue: control cell line. Red: deficient cell lines extracted from patients with well characterized mutations in each of the enzymes ACADM:p[K604E] Black: Background fluorescence was determined with the supplied negative control.

  • Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)
    Flow Cytometry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)

    After background subtraction, the ACADM deficient cell line shows a 57% reduction in the level of the ACADM protein.

  • Immunocytochemistry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)
    Immunocytochemistry - Fatty Acid Oxidation Human Flow Cytometry Kit (ab118183)
    Antibody specificity demonstrated by immunocytochemistry. Cells were processes with the Flow cytometry protocol as explained above. Panel A shows control fibroblasts and panel B shows deficient fibroblasts. Left panel shows staining with anti-ACADVL ab, center panel with anti-ACADM ab and right panel with anti-HADHA ab.

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

Clear all

Recently viewed products

  •  
  • Product image

    Anti-MED19 antibody (ab229325)

  •  
  • Product image

    Anti-IL-12RB2 antibody (ab198833)

Get resources and offers direct to your inbox Sign up
© 2021 Astana Biomed Group LLP. All rights reserved.