Anti-Kallikrein 7/KLK7 antibody [EPR22594-203] - BSA and Azide free (ab255328)
Key features and details
- Produced recombinantly (animal-free) for high batch-to-batch consistency and long term security of supply
- Rabbit monoclonal [EPR22594-203] to Kallikrein 7/KLK7 - BSA and Azide free
- Suitable for: IHC-P, IHC-Fr, WB
- Reacts with: Mouse, Rat, Human
Overview
-
Product name
Anti-Kallikrein 7/KLK7 antibody [EPR22594-203] - BSA and Azide free
See all Kallikrein 7/KLK7 primary antibodies -
Description
Rabbit monoclonal [EPR22594-203] to Kallikrein 7/KLK7 - BSA and Azide free -
Host species
Rabbit -
Tested applications
Suitable for: IHC-P, IHC-Fr, WBmore details
Unsuitable for: ICC/IF or IP -
Species reactivity
Reacts with: Mouse, Rat, Human -
Immunogen
Recombinant fragment. This information is proprietary to Abcam and/or its suppliers.
-
Positive control
- WB: Mouse skin lysate; rat skin lysate. IHC-P: Human skin tissue; mouse skin tissue; rat skin tissue. IHC-Fr: Mouse skin tissue; rat skin tisssue.
-
General notes
ab255328 is the carrier-free version of ab254258.
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. The carrier-free buffer and high concentration allow for increased conjugation efficiency.
This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free production
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Properties
-
Form
Liquid -
Storage instructions
Shipped at 4°C. Store at +4°C. Do Not Freeze. -
Storage buffer
pH: 7.2
Constituent: PBS -
Carrier free
Yes -
Concentration information loading...
-
Purity
Protein A purified -
Clonality
Monoclonal -
Clone number
EPR22594-203 -
Isotype
IgG -
Research areas
Images
-
Immunohistochemical analysis of paraffin-embedded rat skin tissue labelling KLK7 with ab254258 at 1/500 dilution for 30 minutes at room temperature, followed by ready to use rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on stratum corneum of rat skin (PMID 23999494). Hematoxylin used as a counterstain. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) was performed for 20 mins. The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is ready to use rabbit specific IHC polymer detection kit HRP/DAB (ab209101).This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254258).
-
Immunohistochemical analysis of paraffin-embedded mouse skin tissue labelling KLK7 with ab254258 at 1/500 dilution for 30 minutes at room temperature, followed by ready to use rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on stratum corneum of mouse skin (PMID 23999494). Hematoxylin used as a counterstain. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) was performed for 20 mins. The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is ready to use rabbit specific IHC polymer detection kit HRP/DAB (ab209101).This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254258).
-
Immunohistochemical analysis of paraffin-embedded human skin tissue labelling KLK7 with ab254258 at 1/500 dilution for 30 minutes at room temperature, followed by ready to use rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on stratum corneum of human skin (PMID 23999494). Hematoxylin used as a counterstain. Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) was performed for 20 mins. The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254258).
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is ready to use rabbit specific IHC polymer detection kit HRP/DAB (ab209101). -
Immunohistochemical analysis of 0.2% Triton X-100 permeabilised, 4% PFA fixed rat skin tissue labelling KLK7 with ab254258 at 1/100 dilution, followed by AlexaFluor®488 Goat anti-Rabbit secondary (ab150077) at 1/1000 dilution. DAPI was used as nuclear counterstain. Heat mediated antigen retrieval using sodium citrate buffer (10mM citrate pH 6.0 + 0.05% Tween-20) was performed. Specific staining on stratum corneum of rat skin (PMID: 23999494).
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is AlexaFluor®488 Goat anti-Rabbit secondary (ab150077) at 1/1000 dilution.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254258).
-
Immunohistochemical analysis of 0.2% Triton X-100 permeabilised, 4% PFA fixed mouse skin tissue labelling KLK7 with ab254258 at 1/100 dilution, followed by AlexaFluor®488 Goat anti-Rabbit secondary (ab150077) at 1/1000 dilution. DAPI used as nuclear counterstain. Heat mediated antigen retrieval using sodium citrate buffer (10mM citrate pH 6.0 + 0.05% Tween-20) was performed. Specific staining on stratum corneum of mouse skin (PMID: 23999494).
Secondary antibody only control: Used PBS instead of primary antibody, secondary antibody is AlexaFluor®488 Goat anti-Rabbit secondary (ab150077) at 1/1000 dilution.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab254258).
-