Anti-Corin antibody [EPR23361-77] - BSA and Azide free (ab274323)
Key features and details
- Produced recombinantly (animal-free) for high batch-to-batch consistency and long term security of supply
- Rabbit monoclonal [EPR23361-77] to Corin - BSA and Azide free
- Suitable for: IHC-P, WB
- Reacts with: Mouse, Human
Overview
-
Product name
Anti-Corin antibody [EPR23361-77] - BSA and Azide free
See all Corin primary antibodies -
Description
Rabbit monoclonal [EPR23361-77] to Corin - BSA and Azide free -
Host species
Rabbit -
Tested applications
Suitable for: IHC-P, WBmore details
Unsuitable for: Flow Cyt,ICC or IP -
Species reactivity
Reacts with: Mouse, Human -
Immunogen
Recombinant fragment. This information is proprietary to Abcam and/or its suppliers.
-
General notes
ab274323 is the carrier-free version of ab274320. This format is designed for use in antibody labeling, including fluorochromes, metal isotopes, oligonucleotides, enzymes.
Our carrier-free formats are supplied in a buffer free of BSA, sodium azide and glycerol for higher conjugation efficiency.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm.
Maxpar® is a trademark of Fluidigm Canada Inc.
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free production
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Reproducibility is key to advancing scientific discovery and accelerating scientists’ next breakthrough.
Abcam is leading the way with our range of recombinant antibodies, knockout-validated antibodies and knockout cell lines, all of which support improved reproducibility.
We are also planning to innovate the way in which we present recommended applications and species on our product datasheets, so that only applications & species that have been tested in our own labs, our suppliers or by selected trusted collaborators are covered by our Abpromise™ guarantee.
In preparation for this, we have started to update the applications & species that this product is Abpromise guaranteed for.
We are also updating the applications & species that this product has been “predicted to work with,” however this information is not covered by our Abpromise guarantee.
Applications & species from publications and Abreviews that have not been tested in our own labs or in those of our suppliers are not covered by the Abpromise guarantee.
Please check that this product meets your needs before purchasing. If you have any questions, special requirements or concerns, please send us an inquiry and/or contact our Support team ahead of purchase. Recommended alternatives for this product can be found below, as well as customer reviews and Q&As.
Properties
-
Form
Liquid -
Storage instructions
Shipped at 4°C. Store at +4°C. Do Not Freeze. -
Storage buffer
pH: 7.2
Constituent: PBS -
Carrier free
Yes -
Concentration information loading...
-
Purity
Protein A purified -
Clonality
Monoclonal -
Clone number
EPR23361-77 -
Isotype
IgG -
Research areas
Images
-
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Corin antibody [EPR23361-77] - BSA and Azide free (ab274323)
This data was developed using ab274320, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded human cardiac muscle tissue labeling Corin with ab274320 at 1/500 dilution followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on human cardiac muscle (PMID: 11082206). The section was incubated with ab274320 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
-
Anti-Corin antibody [EPR23361-77] (ab274320) at 1/1000 dilution + Mouse heart tissue lysate at 20 µg
Secondary
Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/20000 dilution (Goat Anti-Rabbit IgG, (H+L), Peroxidase conjugated)
Predicted band size: 116 kDa
Observed band size: 100-180 kDa why is the actual band size different from the predicted?This data was developed using ab274320, the same antibody clone in a different buffer formulation.
Blocking and diluting buffer and concentration: Tissue specific protein, highly expressed in heart (PMID: 11082006).
The expression profile observed is consistent with what has been described in the literature (PMID: 29387201, 17996891).
Exposure time: 10 seconds
-
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Corin antibody [EPR23361-77] - BSA and Azide free (ab274323)
This data was developed using ab274320, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded human kidney tissue labeling Corin with ab274320 at 1/500 dilution followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on human kidney. The section was incubated with ab274320 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
-
All lanes : Anti-Corin antibody [EPR23361-77] (ab274320) at 1/1000 dilution
Lane 1 : Human heart tissue lysate
Lane 2 : Human brain tissue lysate
Lysates/proteins at 20 µg per lane.
Secondary
All lanes : VeriBlot for IP Detection Reagent (HRP) (ab131366) at 1/1000 dilution (VeriBlot for IP secondary antibody(HRP))
Predicted band size: 116 kDa
Observed band size: 100-180 kDa why is the actual band size different from the predicted?This data was developed using ab274320, the same antibody clone in a different buffer formulation.
Blocking and diluting buffer and concentration: 5% NFDM/TBST.
Tissue specific protein, highly expressed in heart (PMID: 11082006).
The expression profile observed is consistent with what has been described in the literature (PMID: 29387201, 17996891).
Low expression: human brain (PMID: 11082006).
Exposure time: 3 minutes.
-