Anti-CD33 antibody [EPR23051-101] - BSA and Azide free (ab269461)
Key features and details
- Produced recombinantly (animal-free) for high batch-to-batch consistency and long term security of supply
- Rabbit monoclonal [EPR23051-101] to CD33 - BSA and Azide free
- Suitable for: ICC, WB, IHC-P, IP
- Reacts with: Human
Overview
-
Product name
Anti-CD33 antibody [EPR23051-101] - BSA and Azide free
See all CD33 primary antibodies -
Description
Rabbit monoclonal [EPR23051-101] to CD33 - BSA and Azide free -
Host species
Rabbit -
Tested applications
Suitable for: ICC, WB, IHC-P, IPmore details
Unsuitable for: Flow Cyt -
Species reactivity
Reacts with: Human -
Immunogen
Synthetic peptide. This information is proprietary to Abcam and/or its suppliers.
-
Positive control
- WB: U937 and THP-1 whole cell lysates; Human liver lysate. IHC-P: Human liver, Human Hodgkiin's lymphoma and Human clear cell renal cell carcinoma tissue . ICC/IF: THP-1 cells. IP: THP-1 cells.
-
General notes
ab269461 is the carrier-free version of ab269456. This format is designed for use in antibody labeling, including fluorochromes, metal isotopes, oligonucleotides, enzymes.
Our carrier-free formats are supplied in a buffer free of BSA, sodium azide and glycerol for higher conjugation efficiency.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm.
Maxpar® is a trademark of Fluidigm Canada Inc.
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free production
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Reproducibility is key to advancing scientific discovery and accelerating scientists’ next breakthrough.
Abcam is leading the way with our range of recombinant antibodies, knockout-validated antibodies and knockout cell lines, all of which support improved reproducibility.
We are also planning to innovate the way in which we present recommended applications and species on our product datasheets, so that only applications & species that have been tested in our own labs, our suppliers or by selected trusted collaborators are covered by our Abpromise™ guarantee.
In preparation for this, we have started to update the applications & species that this product is Abpromise guaranteed for.
We are also updating the applications & species that this product has been “predicted to work with,” however this information is not covered by our Abpromise guarantee.
Applications & species from publications and Abreviews that have not been tested in our own labs or in those of our suppliers are not covered by the Abpromise guarantee.
Please check that this product meets your needs before purchasing. If you have any questions, special requirements or concerns, please send us an inquiry and/or contact our Support team ahead of purchase. Recommended alternatives for this product can be found below, as well as customer reviews and Q&As.
Properties
-
Form
Liquid -
Storage instructions
Shipped at 4°C. Store at +4°C. Do Not Freeze. -
Storage buffer
pH: 7.2
Constituent: PBS -
Carrier free
Yes -
Concentration information loading... -
Purity
Protein A purified -
Clonality
Monoclonal -
Clone number
EPR23051-101 -
Isotype
IgG -
Research areas
Images
-
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-CD33 antibody [EPR23051-101] - BSA and Azide free (ab269461)Immunohistochemical analysis of paraffin-embedded Human Hodgkin's lymphoma tissue labeling CD33 with ab269456 at 1/200 dilution (2.96 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Membranous staining on human Hodgkin's lymphoma.
The section was incubated with ab269456 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 20 mins.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab269456).
-
CD33 was immunoprecipitated from 0.35 mg THP-1 (Human monocytic leukemia monocyte) whole cell lysate with ab269456 at 1/30 dilution (2ug in 0.35mg lysates). Western blot was performed on the immunoprecipitate using ab269456 at 1/1000 dilution. VeriBlot for IP Detection Reagent (HRP) (ab131366) was used at 1/5000 dilution.
Lane 1: THP-1 whole cell lysate 10ug.
Lane 2: ab269456 IP in THP-1 whole cell lysate.
Lane 3: Rabbit monoclonal IgG (ab172730) instead of ab269456 in THP-1 whole cell lysate.
Blocking and dilution buffer and concentration: 5% NFDM/TBST.
Exposure time: 23 seconds.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab269456).
-
Immunofluorescent analysis of 100% methanol-fixed THP-1 (human monocytic leukemia monocyte) and Jurkat (human T cell leukemia T lymphocyte) cells labeling CD33 with ab26946 at 1/50 dilution, followed by ab150077 AlexaFluor®488 Goat anti-Rabbit secondary at 1/1000 dilution (Green). Confocal image showing membranous staining in THP-1 cells. The nuclear counter stain is DAPI (Blue). Tubilin is detected with ab195889 Anti-alpha Tubulin antibody [DM1A] - Microtubule Marker (Alexa Fluor® 594) at 1/200 dilution (Red).
Control: Used PBS instead of primary antibody, followed by ab150077 AlexaFluor®488 Goat anti-Rabbit secondary at 1/1000 dilution.Negative control: Jurkat (PMID: 30519686).
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab269456).
-
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-CD33 antibody [EPR23051-101] - BSA and Azide free (ab269461)Immunohistochemical analysis of paraffin-embedded Human clear cell renal cell carcinoma tissue labeling CD33 with ab269456 at 1/200 dilution (2.96 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Membranous staining on infiltrated myeloid cells of human clear cell renal cell carcinoma The section was incubated with ab269456 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 20 mins.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab269456).
-
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-CD33 antibody [EPR23051-101] - BSA and Azide free (ab269461)Immunohistochemical analysis of paraffin-embedded Human liver tissue labeling CD33 with ab269456 at 1/200 dilution (2.96 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Membranous staining on mainly Kuffer cells of human liver (PMID:25721896). The section was incubated with ab269456 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 20 mins.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab269456).
-
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-CD33 antibody [EPR23051-101] - BSA and Azide free (ab269461)Immunohistochemical analysis of paraffin-embedded Human skeletal muscle tissue labeling CD33 with ab269456 at 1/200 dilution (2.96 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Negative control:Human skeletal muscle.
The section was incubated with ab269456 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 20 mins.
This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab269456).
-