Recombinant human IL-12 p70 protein (Active) (ab259418)
Key features and details
- Expression system: HEK 293 cells
- Purity: >= 95% SDS-PAGE
- Endotoxin level:
- Active: Yes
- Suitable for: Cell Culture, SDS-PAGE, HPLC, Functional Studies, MS
Preparation and Storage
-
Stability and Storage
Shipped at Room Temperature. Store at Room Temperature.
Information available upon request.
This product is an active protein and may elicit a biological response in vivo, handle with caution.
-
ReconstitutionReconstitute with phosphate buffered saline. Store lyophilized form at room temperature. Reconstitute, aliquot and store at -80°C for 12 months or +4°C for 1 week. Avoid repeated freeze-thaw.
Images
-
Fully biologically active compared to a standard. ED50 as determined by the dose-dependant proliferation of NK-92 cells is 0.86 ng/mL corresponding to a Specific Activity of 1.16 x 106 IU/mg.
-
SDS-PAGE analysis of ab259418.
Protein is a hetero-dimer.
-
Purity 96%.
The spectrum was recorded using a 1260 Infinity II HPLC system with DAD and a MabPac RP column (3.0x100 mm, 4 µm). 5 µL of purified protein was injected and the gradient run from 80 % water:TFA (99.9:0.1 v/v) and 20 % acetonitrile:water:TFA (90:9.9:0.1 v/v/v) to 20 % water:TFA (99.9:0.1 v/v) and 80 % acetonitrile:water:TFA (90:9.9:0.1 v/v/v) within 3 minutes followed by an isocratic step for another 3 min. Flow rate was 0.5 mL/min and the column compartment temperature was 50 °C.
-
M + 2.8 Da (Calc. mass 22599.2 Da).
The spectrum was recorded with a 6545XT AdvanceBio LC/Q-TOF (Agilent Technologies) and a MabPac RP column (42.1x50 mm, 4 µm, Thermo Scientific). 5 µL of purified protein was injected and the gradient run from 85 % water:FA (99.9:0.1 v/v) and 15 % acetonitrile:FA (90:9.9:0.1 v/v/v) to 55 % water:FA (99.9:0.1 v/v) and 45 % acetonitrile:FA (90:9.9:0.1 v/v/v) within 3 minutes followed by an isocratic step for another 2.5 min. Flow rate was 0.4 mL/min and the column compartment temperature was 60 °C. Data was analysed and deconvoluted using the Bioconfirm software (Agilent Technologies).
-
M + 2.97 Da (Calc mass 34754.03 Da).
The spectrum was recorded with a 6545XT AdvanceBio LC/Q-TOF (Agilent Technologies) and a MabPac RP column (42.1x50 mm, 4 µm, Thermo Scientific). 5 µL of purified protein was injected and the gradient run from 85 % water:FA (99.9:0.1 v/v) and 15 % acetonitrile:FA (90:9.9:0.1 v/v/v) to 55 % water:FA (99.9:0.1 v/v) and 45 % acetonitrile:FA (90:9.9:0.1 v/v/v) within 3 minutes followed by an isocratic step for another 2.5 min. Flow rate was 0.4 mL/min and the column compartment temperature was 60 °C. Data was analysed and deconvoluted using the Bioconfirm software (Agilent Technologies).