Human RHOC ELISA Kit (ab243680)
Key features and details
- One-wash 90 minute protocol
- Sensitivity: 140 pg/ml
- Range: 0.78 ng/ml - 50 ng/ml
- Sample type: Cell culture extracts, Tissue Extracts
- Detection method: Colorimetric
- Assay type: Sandwich (quantitative)
- Reacts with: Human
Overview
-
Product name
Human RHOC ELISA Kit
See all RHOC kits -
Detection method
Colorimetric -
Precision
Intra-assay Sample n Mean SD CV% cell extract 3 5.3% Inter-assay Sample n Mean SD CV% cell extract 7 7.3% -
Sample type
Cell culture extracts, Tissue Extracts -
Assay type
Sandwich (quantitative) -
Sensitivity
140 pg/ml -
Range
0.78 ng/ml - 50 ng/ml -
Recovery
Sample specific recovery Sample type Average % Range Cell culture extracts 97 96% - 98% Tissue Extracts 97 96% - 99% -
Assay time
1h 30m -
Assay duration
One step assay -
Species reactivity
Reacts with: Human -
Product overview
Human RHOC ELISA Kit (ab243680) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of RHOC protein in cell culture extracts and tissue extracts. It uses our proprietary SimpleStep ELISA® technology. Quantitate Human RHOC with 140 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
- Single-wash protocol reduces assay time to 90 minutes or less
- High sensitivity, specificity and reproducibility from superior antibodies
- Fully validated in biological samples
- 96-wells plate breakable into 12 x 8 wells stripsA 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
-
Notes
Abcam has not and does not intend to apply for the REACH Authorisation of customers’ uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses. -
Platform
Pre-coated microplate (12 x 8 well strips)
Properties
-
Storage instructions
Store at +4°C. Please refer to protocols. -
Components 1 x 96 tests 10X Human RHOC Capture Antibody 1 x 600µl 10X Human RHOC Detector Antibody 1 x 600µl 10X Wash Buffer PT (ab206977) 1 x 20ml 50X Cell Extraction Enhancer Solution (ab193971) 1 x 1ml 5X Cell Extraction Buffer PTR (ab193970) 1 x 10ml Antibody Diluent 4BI 1 x 6ml Human RHOC Lyophilized recombinant Protein 2 vials Plate Seals 1 unit Sample Diluent NS (ab193972) 1 x 12ml SimpleStep Pre-Coated 96-Well Microplate (ab206978) 1 unit Stop Solution 1 x 12ml TMB Development Solution 1 x 12ml -
Research areas
-
Function
Regulates a signal transduction pathway linking plasma membrane receptors to the assembly of focal adhesions and actin stress fibers. -
Sequence similarities
Belongs to the small GTPase superfamily. Rho family. -
Cellular localization
Cell membrane. - Information by UniProt
-
Alternative names
- Aplysia RAS-related homolog 9
- ARH 9
- ARH9
see all -
Database links
- Entrez Gene: 389 Human
- Omim: 165380 Human
- SwissProt: P08134 Human
- Unigene: 502659 Human
- Unigene: 658289 Human
Images
-
SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
-
The RHOC standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed.
-
Interpolated concentrations of native RHOC in MCF7, HUVEC, SH-SY5Y, mouse NIH/3T3, and rat liver extracts.
Interpolated concentrations of native RHOC in MCF7, HUVEC, SH-SY5Y, mouse NIH/3T3, and rat liver extracts based on a 300 μg/mL extract load for MCF7 and HUVEC samples, 800 μg/mL for SH-SY5Y sample, 400 μg/mL extract load for NIH/3T3 and rat liver samples. The concentrations of RHOC were measured in duplicate and interpolated from the RHOC standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).
-
To learn more about the advantages of recombinant antibodies see here.